beautypg.com

Installation of optional accessories – Flowserve FPS 14 User Manual

Page 11

background image

Installation of Optional Accessories

Cycle Counter

The cycle counter is installed by screwing the pneumatic cylinder into one of the ¼” NPT

connections on top of the cover flange. The force of the pressurizing gas lifts the counter
arm for each cycle.

Freeze Protection Drain Valve

If the pump is to be installed outside, or anywhere that freezing is a threat, a Freeze
Protection Drain Valve should be installed on the ½” NPT drain connection on the bottom

of the tank. A pipe should be installed after the drain valve so that the discharge is visible.
See the instructions provided with the valve for more detailed installation directions.

Gauge Glass Assembly

2 Valves, 2 Rods, 1 Glass, 2 ¾” NPT Short Nipples, and 2 ¾” NPT Unions

This assembly is installed on the two (2) ¾” NPT connections on the front of the tank. The

valve with the drain connection must be installed in the bottom connection. The ¾” short
nipples and unions are threaded into the top and bottom tank connections. The valve is

threaded into the mating part of the ¾” union. It is very important that the top and bottom

valves line up before the glass is installed, or else the glass will break. The glass is installed
into the bottom valve, and the top valve is fitted over the top of the glass, and the union is

tightened. Tighten the two (2) fittings that hold the glass and install the guard rods.

Insulation Blanket

Wrap the main blanket piece around the pump tank so that the opening is on the same

side as the two (2) ¾” NPT couplings on the front of the tank. Fasten the front seam and
the two (2) end pieces, (if required) using the supplied stainless steel wire.

Pressure Gauge

Install the pressure gauge, with the syphon loop (pigtail), in one of the ¼” NPT connections

on the top of the cover flange.

Pressure Reducing Valve

The PRV must be installed upstream of the pump mechanism on the motive gas supply line.

The pressure must be regulated below 200 psig, unless a special tank has been ordered. See
the instructions provided with the valve for more detailed installation instructions.

Safety Relief Valve

A safety relief valve set at or below 200 psig, and a pressure gauge should also be installed

between the PRV and the pressure valve connection on to of the cover flange. This will
protect the pump in case the PRV fails. See the instructions provided with the valve for

more detailed installation instructions.

GESTRA GmbH

Postfach 10 54 60
D-28054 Bremen

Hemmstraße 130
D-28215 Bremen

Tel. + 49 (0) 421 35 03 - 0
Fax + 49 (0) 421 35 03 - 393
E-mail [email protected]
Internet www.gestra.de

An Invensys company

®

A Unit of Flowserve Corporation