Important Notes
Usage for the intended purpose
Use steam trap BK 27N only for the discharge of condensed water in pipe lines or for air-venting within
the admissible pressure/temperature ratings.
Check the corrosion resistance and chemical suitability of the steam trap for the application in question.
Danger
The steam trap is under pressure during operation.
When loosening flanged connections, plugs or the regulator, hot water and/or steam may
escape. This presents the risk of severe scalding.
Installation and maintenance work should only be carried out when the system is
depressurized (0 bar): isolate the trap from both upstream and downstream pressure.
The trap becomes hot during operation. This presents the danger of severe burns to
hands and arms. Installation and maintenance work should only be carried out when
the system is cold (20 °C).
Sharp edges on internal parts present a danger of cuts to hands. Always wear industrial
gloves when replacing the regulator or the strainer.
Safety note
The equipment must only be installed and commissioned by qualified staff.
Maintenance and service work must only be performed by adequately trained persons who have
a recognised level of competence.
Attention
The name plate specifies the technical features of the equipment. Note that any piece of
equipment without its specific name plate must neither be commissioned nor operated.
The equipment does not have its own potential source of ignition and is therefore not subject to the
ATEX Directive 94/9/EC.
The equipment can be used in potentially explosive areas 0, , 2, 20, 2, 22 (999/92/EC).
The equipment is not Ex market.
PED (Pressure Equipment Directive)
The equipment fulfills the requirements of the PED 97/2/EC. The equipment can be used with fluids
of group 2. With CE marking (except equipment according to section . of the PED).
ATEX (Atmosphère Explosible)