Connect the cables to the terminal strips of the test station according to the wiring diagram.
Wiring
Connecting cables for measuring electrodes
NRG 16-19
The measuring electrode comes with a 2 m long connecting cable and can be directly connected
to the test station NRA -3. To extend the cable use screened two-core cable, e. g. Ölflex 0 CH,
manufactured by LAPP, 2 x 0.5 mm
2
. Max. cable length between measuring electrode and test station
NRA -3: 50 m.
NRG 16-27, NRG 16-28
Use screened five-core cable, e. g. Ölflex 0 CH, manufactured by LAPP, 5 x 0.5 mm
2
. Max. cable
length between measuring electrode and test station NRA -3: 50 m. Please connect the screen to the
measuring electrode.
Pre-assembled connecting cables (with connector) of various lengths available as accessories.
Wiring
n
Screwdriver for cross recess head screws, size and 2
n
Screwdriver for slotted screws, size 2.5, completely insulated to VDE 0680.