Corrosion resistance
Provided that the equipment is used for its intended purpose, its safety is not impaired by corrosion.
Sizing
The body must not be subjected to sharp increases in pressure. Welds and flanges of the electrode are
designed to withstand dynamic loading (bending and alternating stress). The dimensional allowances
for corrosion reflect the latest state of technology.
ER 50-1, ER 56-1
Technical Data
Type approval
TÜV · WR/WB · 03-30
Service pressure 
ER 50-: 6 bar g at 59 °C
ER 56-: 3 bar g at 38 °C
Connection 
Screwed " to EN ISO 8-
Materials 
Stem:
.457 CrNiMoTi7--
Body:
.457
Flange:
.0460 C.8
Measuring electrodes: .457 CrNiMoTi7--
Electrode insulation: PTFE
Spacer disks:
PTFE
Lengths supplied
000 mm, 500 mm
Response sensitivity 
0 μS/cm at 5 °C, cell constant 0.3 cm
–
0.5 μS/cm, depending on level switch NRS -...
Electrical connection 
Four-pole connector, cable gland M 6
Protection 
IP 65 to EN 6059
Max. admissible ambient temperature 
70 °C
Weight 
Approx. 0.8 kg