Checking Oil Level
1.
Actuator should be in full CW position for DA ac-
tuator or failed position for SR actuator.
2.
Remove cap from oil reservoir and check oil
level.
3.
Oil level should be 2-3 inches from top of reser-
voir. If required, add hydraulic fluid to reservoir to
reach this level.
Pump/Oil Specifications
Temperature: 0°F to 300°F
Oil Type: Fire resistant, Nuclear Approved hydraulic
fluid, such as Exxon Firexx HS68. Consult
factory for seal compatibility and temperature
ranges of other fluids.
Oil Volume:
Actuator
SR/DA
Volume (gal)
RN2
SR
1/2
DA
1/2
RN3
SR
1/2
DA
3/4
RN4
SR
1
DA
1 1/2
Pump Pressure: DA
1500 psi
SR
3500 psi
Number of strokes to override:
Actuator
SR/DA
# Pumps
RN2
SR
17
DA
9
RN3
SR
45
DA
25
RN4
SR
132
DA
74
B00151-0
Page 3 of 4
11444 Deerfield Road
Cincinnati, Ohio 45242
(513) 489-7800
FAX (513) 489-5243
Heavy Duty Hydraulic Override
Nuclear Qualified Actuator
Bolt Torques
Piston Bolt (3) (SAE Grade 8 Bolt)*
Actuator Size
Bolt Size
Torque Range
RN2
3/4"-10 UNC
271-320 ft.lb.
RN3
1 1/4"-7 UNC
537-591 ft.lb.
RN4
1 1/4"-7 UNC
1014-1116 ft.lb.
* Not present in SR overrides
Tie Rod (7) (A311 Stressproof Rod)
Actuator Size
Bolt Size
Torque Range
RN2
5/8"-11 UNC
117-130 ft.lb.
RN3
3/4"-10 UNC
207-229 ft.lb.
RN4
1"-8 UNC
249-270 ft.lb.
Adapter Nut (12) and Stud (ASTM A193 Gr. B7)*
Actuator Size
Bolt Size
Torque Range
RN2
1/2"-13 UNC
64-71 ft.lb.
RN3
3/4"-10 UNC
226-249 ft.lb.
RN4
1"-8 UNC
546-603 ft.lb.