Storage & Preservation
When dispatched, all actuators are prepared for storage. All protective
packaging, end cap port plugs, pinion covers etc. should remain in
position until the actuator is due to be installed.
Actuator Markings
Each actuator has the following identification information on the
product label attached to the side of the body:
ATEX Directive
If the product label carries the ATEX Directive number ‘94/9/EC’
followed by the Explosion Protection Symbol and codes identifying the
equipment group and category, the zone suitability and protection type
beside the CE mark, the product complies with the ATEX Directive and
The Equipment and Protective Systems Intended for Use in Potentially
Explosive Atmospheres Regulations 1996.
Definition of product label marking above
‘II’ = Equipment Group;
‘2’ = Equipment Category;
G’ = Gas Zone suitability (Zones 1 & 2);
‘D’ = Dust Zone suitability (Zones 21 & 22);
‘c’ = type of protection i.e. constructional safety (prEN 13463-5).
Surface Temperature
As per EN 13463-1:2001(E) paragraph 14.2.g, the temperature class or
maximum surface temperature cannot be marked on the product as it is
dependant on the operating conditions.
The operational temperature range is as follows:
(S) Standard -30°C to +80°C.
(L) Low Temperature variant -50°C to +80°C.
(H) High Temperature variant -30°C to +150°C.
NOTE: Under constant use the surface temperature of exposed parts
may rise by a maximum 20ºC above the operating media temperature.
SX Series SuperNova™ Actuator
FCD AXENIM0113-00 – 1/06
Additional Safety
Information