Installation Instructions
The Automax A25N directional valve is installed very
easily to any SuperNova series actuator.
1. Place the O-rings provided into the O-ring bores on the face of
the valve. Each O-ring should be completely seated in the bore.
2. Place the actuator with the two ports facing you, and the pinion
pointing up. Orient the Automax solenoid valve with the (3)
O-rings toward the actuator and the operator towards the right.
(The small O-ring is for use with the optional APS1 module).
3. The valve is then mounted to the actuator with the two screws
provided. Apply Locktite Threadlocker 222 or equal to the
screws prior to assembly.
4. Connect the air supply to port #1 and wire solenoid per local
and national electrical codes. The assembly is now ready for
operation.
5. Optional porous bronze vents (P/N 101602) or adjustable
speed controls (P/N 100531) can be added to ports #3 & #5.
6. The A25N directional valve is easily converted from 4-way to
3-way configuration (see figures below). Move the conversion
screw from the front of the body to the NAMUR port (port #2)
on the back of the valve for 3-way operation. Apply a small
amount of thread sealant to eliminate leakage past the
conversion screw.
Ordering Example: Automax 4-way solenoid valve with NEMA 4X, 7 & 9 operator, spring return,
120 VAC / 60 HZ would be: A25NAAXR1
For other options - consult factory.
Automax A25N
Spool Type
Body Type
Operator Spring
Voltages
A- 2-position 4-way
A- single operator
A - Remote air pilot D - 3 position spring center
1- 110/50, 120/60
C- 3-position 4-way - B- dual operator
W - NEMA 4X R - 2 position spring return
2- 220/50, 240/60, 120VDC
blocked center
X - NEMA 4X, 7 & 9
Repeat operator code for
3- 12VDC, 22/50, 24/60
F- 2-position 3-way
I - Intrinsically Safe
2 position, dual operator
4- 24VDC
L - Low Power
5- 15.5VDC Nom. (30VDC Max.)
(12 & 24VDC only)
(intrinsically safe only)
V - 1.8 Watt Low Power
NEMA 4X, 7, & 9
Ordering Guide
LUBRICATION:
• Lubrication of AUTOMAX products is not required
but is recommended to maximize service life. Where
devices not made by AUTOMAX are used in the system
the manufacturer should be consulted regarding their
lubrication requirements.
• Lubricators should be installed downstream of regulators
per the manufacturer's instructions.
• AUTOMAX positioner supply air must be clean, dry and
oil free. Do not use lubricators in conjunction with
AUTOMAX positioners.
• Oils used in air line lubricators should be compatible with
seals used in the system. Generally AUTOMAX products use
Buna-N (Nitrile) with Viton seals available as an option.
Oils should be petroleum based with oxidation inhibitors,
an ISO 32 or lighter viscosity, and an aniline point between
82
°C (180°F) and 104°C (220°F).
Note: See appropriate IOM's for installation of
sandwich NAMUR mount accessories.
4-way Configuration
Air Supply
(Port #1)
1/4˝ NPT
SuperNova
Actuator
NEMA 4x
Operator
24˝ Leads
M5 x 30mm
Socket Head Screws
#5
#3
O-ring
(2) 105775
O-ring
(1) 103606
NEMA 4X, 7 & 9
Operator
Conversion Screw
3-way Configuration
1/4" NPT
CONVERSION SCREW
CONVERSION SCREW