Worcester actuation systems – Flowserve 75 10-23 Series Motor Module User Manual
Page 2

Flow Control
Worcester Actuation Systems
2
Series 75 10-23 Motor Module
FCD WCAIM2066-00
When the motor module is located with “output-slow” clos-
est to center shaft, connect actuator wires as shown except 
interchange grey and yellow motor leads at the motor capacitor 
(12 and 22 size actuators). If capacitor has metal retaining ring, 
insulating fi ber washer must be used.
For 20 75 actuators, 100% duty cycle, the motor module is 
mounted to the actuator with the “output-slow” closest to the 
center shaft. As before, interchange the grey and yellow leads 
from the motor at the capacitor. If capacitor has metal retaining 
ring, insulating fi ber washer must be used.
SPECIAL NOTE
DC Actuators: Observe the following when installing DC motor 
modules:
When the motor module is located with “output-fast” closest to 
the center shaft, connect actuator wires as shown (10 and 20 
size actuators). For 23 size only, wires are connected as shown, 
except that motor module is located with “output-slow” closest 
to center shaft.
When the motor module is located with “output-slow” closest 
to the center shaft, connect actuator wires as shown, except 
interchange the wiring location of the motor’s red and black 
leads. The black wire(s) are connected to terminal 1, while the 
red wire(s) are crimped with the blue wires (12 and 22 size 
actuators).
Alternatively, the supply voltage polarity may be reversed to 
accomplish the same thing. That is, if the motor module is 
located with “output-slow” closest to the center shaft, simply 
reverse supply voltage polarity for proper operation. Never do 
both!
If in special circumstances DC motor is mounted on top of gear-
box from AC motor module, the bearing from gearbox has to be 
removed to eliminate bindings. (DC motor has two bearings in 
the housing already.)