9. Install the Thrust Housing (pc# 2) with O-Ring (pc# 15) onto the Housing (pc# 1) and Drive Sleeve (pc# 6) using Socket Head Cap Screws (pc# 9).
a
CAUTION: Care must be taken to ensure that the O-ring located in the Thrust Base is not damaged during installation.
10. Install the upper Thrust Roller Bearing (pc# 33) into the Thrust Housing (pc# 2).
11. Install the Stem Nut (pc# 5) into the Thrust Housing (pc# 2) and upper Thrust Roller Bearing (pc# 33).
12. Install the lower Thrust Roller Bearing (pc# 33) onto the Stem Nut (pc# 5).
13. Place the Gasket (pc# 32) onto the Thrust Housing (pc# 2).
14. Separately, install the O-Ring (pc# 15) into the Thrust Base (pc# 31).
15. Install the Thrust Base (pc# 31) with O-Ring (pc# 15) onto the Thrust Housing (pc# 2) and Stem Nut (pc# 5) using Socket Head Cap Screws
(pc# 34).
a
CAUTION: Care must be taken to ensure that the O-ring located in the Thrust Base is not damaged during installation.
16. Place the gearbox in the upright position.
17. Install the Stem Cover Adapter (pc# 28) and O-Rings (pc# 26 and pc# 27) on the Housing (pc# 1).
18. Separately, install the Bearings (pc# 11), Collar (pc# 16), Bearing (pc# 12), and additionally for V35H and V4H only, the Retaining Ring (pc#
29). For V5H–V9H, install the Bearing Washer (pc# 18) and Bearing Nut (pc# 17) onto the Bevel Pinion (pc# 4).
19. Install the Bevel Pinion subassembly into the Housing (pc# 1).
20. Replace the Oil Seal (pc# 25) in the Input Flange (pc# 8), if required.
21. Place the Gasket (pc# 21) onto the Housing (pc# 1) and install the Input Flange (pc# 8) or the Spur Gear Attachment (See Section 5.3 or 5.4).
a
CAUTION: For proper backlash of the bevel gear set, ensure supplied gaskets and shims (if applicable) are placed between the Input Flange (or
Spur Gear Attachment) and Housing.
NOTE: Ensure binding does not occur between the Bevel Pinion and Bevel Gear
NOTE: Lubricate all Oil Seals before installation