Flowserve V901 VariCool Desuperheater User Manual
Page 8
- 8 -
Defect
No.
Possible cause
Remedy
Excessive valve seat leakage
4.1
4.2
4.3
•
damaged sealing edges at
valve seat or plug
•
foreign particles in seat area
•
plug does not close fully
•
contact customer services
department or contract partner
•
contact customer services
department or contract partner
•
refer to 3.1 to 3.5
Leaking stuffing box system
5.1
5.2
5.3
5.4
•
compression force on packing
too low
•
worn packing
•
dirty spindle
•
damaged spindle
•
slightly re-tighten stuffing box packing
Caution: make sure the valve spindles
can still move !
•
slightly re-tighten stuffing box packing
Caution: make sure the valve spindles
can still move !
•
if the packing does not stop leaking,
contact customer service department
or contract partner
•
clean spindle with suitable cleaning
agent
•
contact customer services
department or contract partner
Leaking top or lid seal
6.1
6.2
•
pressing force on seal(s) too
low
•
seal(s) defective
•
properly re-tighten top or lid nuts
crosswise
•
contact customer services
department or
contract partner
Leaking housing
7.1
•
medium or flow related damage
•
contact customer service department
or
contract partner
No limit switch signal
8.1
8.2
•
power supply to limit switch
interrupted
•
limit switch misadjusted
•
check power supply ( voltage, circuit
breakers, connections )
•
readjust limit switch; operating
distance see limit switch data sheet
Vibrating positioner
9.1
•
defective positioner
•
see maintenance and operating in
structions of positioner manufacturer
If the problem is not solved by taking the above measures, contact the customer services
department or contract partner.