8 Troubleshooting chart

Problem

Possible cause

Corrective Action

Stem pulsates

1. Unstable air supply

2. Adjust air supply

2. Vent or passage blocked

3. Clean vent or passage

Actuator slow

1. Air supply too low

1. Adjust air supply

2. Diaphram case leaks air

2. Seal diaphram case

3. Spring case vent blocked

3. Renew vent

Actuator will not

1. Air supply too low

1. Adjust air supply

return to end

2. Broken actuator spring

2. Renew all actuator springs

position

3. Actuator movement blocked

3. Dissassemble actuator and check

Actuator will not

1. Actuator not vented

1. Vent actuator

return to the

2. Broken actuator spring

2. Renew all actuator springs

failsafe position

3. Actuator movement blocked

3. Dissassemble actuator and check

All data subject to change without notice

©04.2002 Flowserve Corporation. Flowserve and Kämmer are trademarks of Flowserve Corporation

Regional Headquarters

Flowserve

Flowserve

Flowserve

Manderscheidtstr. 19

1350 N. Mt. Springs Prkwy.

12 Tuas Avenue 20

45141 Essen

Springville, UT 84663

Germany

USA

Singapore 638824

Telephone: +49 (0) 201 8919 5

Telephone: +1 801 489 8611

Telephone: +65 862 3332

Facsimile: +49 (0) 201 8919 662

Facsimile: +1 801 489 3719

Facsimile: +65 862 4940

Main Sales Offices (Europa, Middle east, Africa)

Flowserve

Flowserve

Flowserve

Flowserve

von-Braun-Straße 19a

12, av. du Québec

Station Road

Allee du Quartz 1

48681 Ahaus

91965, Courtaboeuf Cedex

Pershore, Worcestershire

CH-2300 La-Chaux-de Fonds

Germany

France

England WR102BZ

Switzerland

Telephone: +49 (0) 2561 6860

Telephone: +33 (0) 1 60 923 251

Telephone: +44 (0) 1386 55 45 51

Telephone: +41 (0) 32 925 9700

Facsimile: +49 (0) 2561 68648

Facsimile: +33 (0) 1 60 923 299

Facsimile: +44 (0) 1386 55 49 68

Facsimile: +41 (0) 32 926 5422

Flowserve

Flowserve

Cnr. Bismit and Granier Str.

C/O Saleh & Abdulaziz Abahsain

Jet Park Ext 3

P.O. Box 209

Boksburg
1459 Gauteng

Al Khobar 31952

South Africa

Saudi Arabia

Telephone: +27 397-3150

Telephone: 9663 857 3442

Facsimile: +27 397-5300/01/02

Facsimile: 9663 859 5284