beautypg.com

Flowserve 051 000 Series User Manual

Page 5

background image

5

Flow Control

Kämmer Control Valves

®

6

REMOVE AND INSTALL ACTUATOR

General Information

We recommend separating the actuator from the valve

during all repair work. However, many maintenance and

adjusting operations can be carried out in an installed

condition.

6.1

Remove series 4 actuator

(see Fig 1)

To remove series 2 actuator see 6.3

6.1.1 Shut off air supply.

DANGER: Depressurise the line to atmospheric

pressure and drain all fluids from the valve before

working on the actuator. Failure to do so can cause

serious injury.

6.1.2 As required remove any outside tubing.
6.1.3 Remove cap and nameplate. Tighten zero adjusting nut

until it just touches the surface of the spring housing.

This relieves the plug from actuator spring pressure. If

the actuator is fitted with a handwheel this can be used

to relieve the plug from actuator spring pressure.

6.1.4 Using a wrench, secure the actuator stem against

turning and using a second wrench loosen the stem

locknuts. If the actuator is fitted with a coupling refer

to the procedure described in the maintenance instruc-

tions for the I/P actuator.

NOTE: the actuator stem must not be rotated, as this

will cause damage to the diaphragm.

6.1.5 Loosen gland and clamp nuts.
6.1.6 Secure plug stem against turning and unscrew actuator

from plug stem by rotating counter-clockwise.

NOTE: Ensure that the plug assembly is not rotated with

the plug seated. This may cause irreparable damage to

the seating faces.

6.1.7 Remove actuator and remove at the same time locknut,

travel indicator disc, gland nut and clamp nut.

6.2

Install series 4 actuator

Information:

• Before the actuator is installed, it must be calibrated

according to section 8 of the instructions „Pneumatic

and Electro-pneumatic Actuators“.

• All worn or damaged parts must be replaced. Reus-

able parts must be clean.

6.2.1 Position actuator with clamp nut, gland nut, locknuts

and travel indicator disc on the valve.

6.2.2.1 Only for „spring-to-close“ valves:

Screw actuator onto plug stem by rotating clockwise,

until the yoke plate just touches the valve housing and

the actuator is aligned forward. If the actuator is fitted

with a coupling refer to the procedure described in the

maintenance instructions for the I/P actuator.

NOTE: Ensure that the plug assembly is not rotated

with the plug seated. This may cause irreparable dam-

age to the seating faces.

6.2.2.2 Only for „spring-to-open“ valves:

Lift plug stem and screw it into the lower coupling half

until the distance between „plug in seat“ and „plug

raised“ approximately corresponds to the specified

stroke.

6.2.3 Tighten clamp nut and gland nut.
6.2.4 Adjust seat tightness by screwing/unscrewing the plug

stem in/out of the actuator stem.

NOTE: Ensure that the plug assembly is not rotated

with the plug seated. This may cause irreparable dam-

age to the seating faces. Open valve, make adjustment,

close valve and check for leaks. If the valve is fitted

with a bellows seal the plug stem may NOT be rotated

at all. In the case of a bellows seal adjustments are

made with the coupling.

6.2.5 After adjusting, secure the locknuts and the travel

indicator disc lying between them against actuator

stem and align the travel indicator on the yoke rod.

6.3

Remove series 2 actuator

(see Fig. 1a)

For series 4 actuator see 6.1

6.3.1 Shut off air supply.

DANGER: Depressurise the line to atmospheric

pressure and drain all fluids from the valve before

working on the actuator. Failure to do so can cause

serious injury.

6.3.2 Disconnect all tubing.
6.3.3 Remove 2 screws and remove coupling.
6.3.4 Remove yoke rod retaining nuts and lift actuator

assembly from the valve.

6.3.5 Remove coupling insert and it’s locknut from plug

stem.

NOTE: Ensure that the plug assembly is not rotated

with the plug seated. This may cause irreparable

damage to the seating faces.

6.4

Install series 2 actuator

(see Fig. 1a)

The actuator stem must be fully extended:

Actuators with air-to-open action must be fully

vented. Actuators with air-to-close action apply

supply pressure.

Manually depress the plug stem to ensure the plug

is fully seated.

6.4.1 Screw coupling insert locknut and coupling insert as

far as possible onto plug stem.

6.4.2 Place the actuator assembly on the valve engaging the

yoke rod threads in the lower yoke plate and ensuring

the actuator faces in the correct direction.