Technical data, Common data, Other data – Flowserve PMV P3 User Manual
Page 20

20
10. Technical data
Common data
Repeatability
<0,3%
Air delivery Supply at 600 kPa
125 nl/min
Air delivery Exhaust at 600 kPa
125 nl/min
Air supply pressure range
140-600kPa
Gain % / % acc. to ISA S75
5 to 30 %/%
Temperature range
-40
°C to +85°C
Temperature sensitivity
< 0.4% per 10
°C
Stroke length
6 - 60 mm, option 3 mm
Other data
P3
Linearity
<
±1%
Hysteresis + Deadband
<0.5%
Deadband
<0.15%
Air consumption (depending on gain setting)
2-8 nl/min
Supply pressure sensitivity
<0.20%
Input signal
0.2 - 1 bar (3 - 15 psi)
EP3
Linearity
<
±1.5%
Hysteresis + Deadband
<1%
Deadband
<0.2%
Air consumption (depending on gain setting)
4-10 nl/min
Supply pressure sensitivity
<0.3%
Input signal
4 - 20 mA
EP3EX
Linearity
<
±1.5%
Hysteresis + Deadband
<1%
Deadband
<0.2%
Air consumption (depending on gain setting)
4-10 nl/min
Supply pressure sensitivity
<0.3%
Input signal
4 - 20 mA