5. Place the nozzle block (113) on the upper dia-
phragm (112) with the nozzle down, aligning the
hole in the corner with the orifice in the I/P base
(109).
6. Place the lower diaphragm (114, with four holes)
onto the assembly with the convolution facing up,
aligning the four holes appropriately.
7. Place the vent block (115) on the assembly with the
vent hole on the side aligned with the NPT opening.
Be certain the mounting holes and pneumatic pas-
sages are aligned.
8. Place the booster diaphragm and vent assembly
(116) on the assembly with the brass vent assem-
bly facing up. Be certain the large holes in the small
pneumatic passages are aligned.
9. Place the large booster spring (117) on the dia-
phragm and over the brass vent assembly.
10. Place the connection block (118) on the assembly
with the plugged hole facing opposite the electrical
NPT connection.
11. Tighten the entire booster section together with the
two housing bolts (119).
Troubleshooting
Failure
Probable Cause
Corrective Action
Operation erratic and
1. Loose signal wire connection
1. Tighten signal wire connection
inconsistent
2. Dirt build-up on flapper and nozzle
2. Remove dirt build-up; see "Cleaning
Flapper and Nozzle " section
Won't calibrate to full span
1. Dirt build-up on nozzle and flapper
1. Remove dirt build-up; see "Cleaning
with normal air pressure
Flapper and Nozzle" section
2. Air supply pressure too high or low
2. Adjust air supply to 20 psi
Excessive air consumption
1. Ruptured diaphragm
1. Replace diaphragm; see
"Disassembling and Reassembling
Booster" section
2. Housing bolts loose
2. Tighten housing bolts
Transducer does not
1. Plugged orifices
1. Clean orifices; see Disassembling
respond to singnal
and Reassembling Booster" secton
2. Shorted or open circuit coil
2. Replace transducer
Flowserve Corporation has established industry leadership in the design and manufacture of its products. When properly selected, this Flowserve product is designed to perform its
intended function safely during its useful life. However, the purchaser or user of Flowserve products should be aware that Flowserve products might be used in numerous applications
under a wide variety of industrial service conditions. Although Flowserve can (and often does) provide general guidelines, it cannot provide specific data and warnings for all possible
applications. The purchaser/user must therefore assume the ultimate responsibility for the proper sizing and selection, installation, operation and maintenance of Flowserve products.
The purchaser/user should read and understand the Installation Operation Maintenance (IOM) instructions included with the product, and train its employees and contractors in the safe
use of Flowserve products in connection with the specific application.
While the information and specifications presented in this literature are believed to be accurate, they are supplied for informative purposes only and should not be considered certified or
as a guarantee of satisfactory results by reliance thereon. Nothing contained herein is to be construed as a warranty or guarantee, express or implied, regarding any matter with respect
to this product. Because Flowserve is continually improving and upgrading its product design, the specifications, dimensions and information contained herein are subject to change
without notice. Should any question arise concerning these provisions, the purchaser/user should contact Flowserve Corporation at any of its worldwide operations or offices.
For more information, contact:
For more information about Flowserve, contact www.flowserve.com or call USA 972 443 6500
Regional Headquarters
1350 N. Mt. Springs Prkwy.
Springville, UT 84663
Phone 801 489 8611
Facsimile 801 489 3719
12 Tuas Avenue 20
Republic of Signapore 638824
Phone (65) 862 3332
Facsimile (65) 862 4940
Flowserve and Valtek are registered trademarks of Flowserve Corporation.
12, av. du Québec, B.P. 645
91965, Courtaboeuf Cedex,
France
Phone (33 1) 60 92 32 51
Facsimile (33 1) 60 92 32 99
Quick Response Centers
5114 Railroad Street
Deer Park, TX 77536 USA
Phone 281 479 9500
Facsimile 281 479 8511
104 Chelsea Parkway
Boothwyn, PA 19061 USA
Phone 610 497 8600
Facsimile 610 497 6680
1300 Parkway View Drive
Pittsburgh, PA 15205 USA
Phone 412 787 8803
Facsimile 412 787 1944
©1998 Flowserve Corporation. Flowserve Corporation, Valtek Control Products, Tel. USA 801 489 8611