11.0 BOLTING TORQUE VALUES
At intervals of not more than six months, check the tightness of all bolting. The recommended torque values for all bolting are
shown below:
VALVE SIZE ½", ¾"
Torque (ft-lb)
Part #
Size
Description
Material
Nominal
Maximum
231
¼"-20
Yoke Nut
A194-2H
10
15
234
¼"-20
Gland Stud Nut
A564-630-1150
1
4
240
5/8"-18
Handwheel Nut
Carbon Steel
15
20
VALVE SIZE: 1"
Torque (ft-lb)
Part #
Size
Description
Material
Nominal
Maximum
231
¼"-20
Yoke Nut
A194-2H
10
15
234
5/16"-18
Gland Stud Nut
A564-630-1150
2
6
240
3/4"-16
Handwheel Nut
Carbon Steel
25
30
VALVE SIZE: 1½"
Torque (ft-lb)
Part #
Size
Description
Material
Nominal
Maximum
231
5/16"-18
Yoke Nut
A194-2H
20
25
234
3/8"-16
Gland Stud Nut
A564-630-1150
4
12
240
1"-14
Handwheel Nut
Carbon Steel
50
60
VALVE SIZE: 2"
Torque (ft-lb)
Part #
Size
Description
Material
Nominal
Maximum
231
3/8"-16
Yoke Nut
A194-2H
35
40
234
3/8"-16
Gland Stud Nut
A564-630-1150
5
15
240
1"-14
Handwheel Nut
Carbon Steel
25
30
NOTE: The above table provides nominal design torque values and maximum torque values using an assumed friction
coefficient of 0.2. The maximum torque values provide for material conditions such as rust and oxides that exist after
equipment is in service.
800-lb. Split-Wedge Gate Valves FCD ADENIM0002-00