beautypg.com

Maintenance, Type ek/71, Disassembly exchanging the stem sealing – Flowserve Argus Ball Valves User Manual

Page 10: Maintenance)

background image

Argus

Maintenance

10

Maintenance

Type EK/71


EK71-02-001

Danger!
Do not disassemble the valve under pressure. Before disassembly operate valve so that possible
pressure behind the ball may escape.

Disassembly

f Stem (22) should be in CLOSED position.
f Remove snap ring (12) and stop disk (7).
f Detach screws (8, 9) with bush (5).
f Remove cover plate (6) with sealing ring (43), on DN 32-50 with bearing tape (34) and dowel pin, as

well as thrust ring (11) with sealing ring (35).

∗∗

f Unscrew flange connection (2) with sealing ring (33) and O-ring (37) from body (1) using a special

ARGUS tool (eccentric).

f Remove ball (21) and sealing rings (31).
f Press stem (22) downwards and take it out of the body together with bushing (36) and disks (38).
f The O-ring (32) and disk (39) are removed upwards.

Exchanging the Stem Sealing

Proceed as per Disassembly until

(∗∗)

.

f Then exchange disk (39) and O-ring (32). When using a PTFE seal instead of O-ring (32), item (39)

can be left out.

Depending on the requirements, a partial disassembly of the ball valve may be sufficient.

f To reassemble, proceed in reverse order.