Flowserve Seal Gard User Manual
Page 8

Use of the Seal Gard to troubleshoot sealing system problems
Type of
Observation
Cause
Suggested Action
Installation
Flowserve seal
Seal Gard I
Single
• no flow in tube
• seal fluid flow
• check supply pressure
• low flow alarm
interrupted
• clean control valve
• pressure
• correct back pressure
reversal
problem
Seal Gard II
Double
• no flow in tube
• seal fluid flow
• check supply pressure
• low flow alarm
interrupted
• clean control valves
• low pressure
• high pressure
• pressure
• correct back pressure
reversal
problem
• high flow alarm
• inner seal
• close return-from-seal
• low pressure
failure
control valve
• adjust supply control
valve to acceptable
dilution & schedule
seal repair
Seal Gard II
Tandem
• no flow in tube
• seal fluid flow
• check flush source
• low flow alarm
interrupted
• high pressure
• primary (inner) • close supply control
• product in outlet seal failure
valve
• adjust return-from-
seal valve to accept-
able loss level
• route discharge to
approved disposal
• schedule seal repair
8