Table 1 – Flowserve PSS II Supplementary User Manual
Page 2
![background image](https://www.manualsdir.com/files/784362/content/doc002.png)
2
Installation of a PSS II and III on a Goulds 3410 Pump can be simplified
by following the supplemental instructions below. These instructions
should be used in conjunction with the standard PSS II and III Installation
Instructions.
1. After making the appropriate checks and prior to installing the seal,
remove the slingers on the 3410 S and L models (reference Table 1).
If a labyrinth is used on the bearing frame, the seal will not fit. Check
the minimum distance required for PSS II and III installation in Table 1.
Pump Model
3410 S
3410 M
3410 L
3410 XL
Sleeve Diameter
1.750"
2.125"
2.750"
3.000"
and Seal Size
Must Slinger Be
Yes
No
Yes
No
Removed?
Must Centering
Yes
Yes
Yes
No
Devices Be Removed?
Bolt Size and Length
1
/
2
" x 2"
1
/
2
" x 2
1
/
4
"
1
/
2
" x 2
1
/
4
"
1
/
2
" x 2
1
/
4
"
Recommended
long
long
long
long
Number of Bolts
2
2
2
2
Distance from Stuffing
2.38"
2.69"
2.55"
2.94"
Box to Slinger
Distance from Stuffing
2.54"
2.74"
2.70"
3.09"
Box to Bearing Frame*
Distance from Stuffing
-
2.44"
2.18"
-
Box to Labyrinth
Minimum Distance
2.40"
2.62"
2.62"
2.62"
Required For
PSS II and III Installation* *
*This is an approximate dimension which varies from pump to pump.
**Assumes that the centering devices are removed.
Table 1
2. If there is no drain hole in the bottom of the cradle, drill one.
3. Install the seal drive, rotating face, and stationary face per the
standard instructions. Reference FIS145eng, PSS II Installation
Instructions and FIS175eng, PSS III Installation Instructions.
4. Prior to gland installation, remove the gland centering devices from
seals being installed in the 3410 S, M, and L models (reference Table 1).
© Copyright 2005 Flowserve Corporation