2disassembly, 1nomenclature – Flowserve ISC1EX User Manual
Page 2

2
Disassembly
When disassembling seal, inspect for conditions which may have caused the
need for the seal to be removed from service. If seal was removed due to
premature failure, determine what conditions caused that failure and correct any
problems prior to returning the repaired seal to service. For assistance with seal
failure analysis, please contact your Flowserve representative.
2
© Copyright 2001 Flowserve Corporation
These instructions are written for trained, experienced technicians familiar with the basic
principles and tools involved in the installation, care and service of mechanical seals and seal
support systems. A complete reading of these instructions by personnel in contact with the
equipment is essential to safety. Incorrect installation, operation or maintenance can result in
personal injury or death to personnel and damage to the equipment.
1
Nomenclature
Figure 1
Seal Parts that are always replaced
• Rotary unit R
• Mating ring 3
• All O-rings P 11
• Gland gasket G
• Bellows vibration dampener M
• Centering tabs CT and cap screws K
• Cup point and quarter dog set screws 13 13A
Table 1
Reconditionable Seal Parts
• Gland assembly 1
• Sleeve 10
• Sleeve collar 9
Note: Rotary unit (R) consists of
elastomer bellows rotary unit
and single coil spring.
R
Rotary Unit
3
Mating Ring
P
Mating Ring O-ring
11
Shaft O-ring
G
Gasket
1
Gland Assembly
1B
Gland Drive Ring
B
Carbon Bushing
CT
Centering Tab
K
Centering Tab Cap
Screw
10
Sleeve
M
Bellows Vibration
Dampener
9
Sleeve Collar
13
Cup Point Set Screw
13A
Quarter Dog
Set Screw
R
3
M
13
9
1
11
10
G
1B
P
B
13A
CT
K