3.8 Shaft radial run out should be less than 0.13 mm (0.005 inch) FIM (TIR).

See Figure 3. Turn shaft 360° and observe the movement. Excessive

movement may indicate a bent or warped shaft that needs replacement.

Check Radial Shaft Deflection Figure 3

3.9 Make sure all seal housing bores, mounting surfaces, and fluid line connections

are clean and free of burrs and sharp edges that might damage secondary seal-

ing elements (O-rings, V-rings, or gaskets).

4 Wet (impeller side) Cartridge Installation

This section describes the installation of the seal cartridge from the wet or impeller

side of the equipment case. If your cartridge is designed to install from the dry or bear-

ing side of the equipment case, skip to section 5.
4.1 Bolt seal adapter plate to equipment case/pedestal (hand tighten only).
4.2 Locate the seal fit of the adapter to the shaft by use of a dial indicator or center-

ing jig. The equipment shaft must be concentric to the seal adapter bore to

within 0.25 mm (0.010 inch) FIM (TIR). See Figure 4. Seal life can vary with

improper alignment; poor shaft alignment will yield poor seal life.

Center Adapter Plate to Shaft Figure 4

Adapter to be Concentric with Shaft

within 0.25 mm (0.010 inch) FIM (TIR)

Centering Jig

0.13 mm (0.005 inch) FIM (TIR)

Maximum Acceptable Radial Run Out