105677

OWNER’S MANUAL

SPECIFICATIONS

Btu (Variable)

20,000/39,000

Type Gas

Natural Gas
Only

Ignition

Piezo

Manifold Pressure

3.5" W.C.

Inlet Gas

Pressure (in. of water)

Maximum

10.5"

Shipping Weight

30 lbs.

WIRING DIAGRAM

Receiver

Black

On
Off

Remote

Red

Red

White

Thermopile

Gas Control

TPTH

TH

TPTH TP

ACCESSORIES

Purchase these fireplace accessories from
your local dealer. If they can not supply
these accessories, either contact your near-
est Parts Central (see page 28) or call DESA
International’s Sales Department at 1-800-
972-7879 for referral information. You can
also write to the address listed on the back
page of this manual.

MANUAL SHUTOFF
VALVE - GA5010

Manual shutoff valve with 1/8" NPT tap.
Fits 1/2" NPT pipe.

FIREPLACE HOOD

Black - GA6050
Brass - GA6052
Antique Brass - GA6053

Helps deflect heat away from mantel or wall
above fireplace.

LAVA ROCK - GA6060
(Not Shown)

Order when additional rock is desired. (3 lb.
bag)

AUT

O

MAN

OFF

ST

ATUS

ON

LO

HI

TEMP

RECEIVER AND HAND-HELD
THERMOSTAT REMOTE
CONTROL KIT - CGHRCT
SERIES

Allows the gas log heater to be operated in
a manually or thermostatically controlled
mode. You can turn the gas log heater on and
off without ever leaving the comfort of your
easy chair.

RECEIVER AND HAND-
HELD REMOTE CONTROL
KIT - CGHRC SERIES

Allows the gas log heater to be turned on and
off by using a hand-held remote control.

DAMPER CLAMP - GA6080

(Not Shown)

Permanently opens chimney flue damper
for vented operation. Can be used only
with non-thermostat accessories.