FiberPlex FOI-4451 User Manual
Page 11
Rack Mount Solution
The RMC‐3101 (3U, Front Load) and RMC‐2101 (2U, Rear Load) provide up to nine available slots for any fiber
optic isolator or telephone disconnect unit. The tenth available slot must be occupied by a PSM‐3010 or PSM‐
2010 power supply module (chassis dependent). Each RMC will be shipped with one PSM. A second PSM may
also be added for power redundancy, leaving eight available slots for any fiber optic isolator. On the RMC‐
3101, a cable bay is provided below the module bay for cable routing and enhanced air flow through two rear
exhaust fans and a vented front panel.
Each fiber optic isolator must also be installed on
a CMA‐3002 or CMA‐2001 chassis mount
adapter (chassis dependent), which slides the
fiber optic isolator into the slot and assures correct
alignment of the isolator power connector to the
power bus inside the RMC.
FiberPlex recommends the RMC‐3101R for TEMPEST
or other high security applications.
Figure 5 Installation on a CMA‐3002
Figure 4 Installation into an RMC‐3101