6

V23 Flush Receiver


Option: Floor Sensor
NTC 10kOhms at 25°C

1.

Presentation


-

The V23 receiver is a Wall mounting receiver, specially designed to control electrical floor heating regulation in combination

or not with a wireless thermostat V22 type.
-

This couple (Thermostat Receiver) can also be managed by a Central V24 to have full control of your heating installation

from one point.
-

Possibility to connect a floor sensor directly on this unit (For regulation or floor limitation).
















2.

Technical characteristics

Environment. (Temperatures)
Operating :
shipping et storage :


0°C - 40°C
-10°C to +50°C

Power supply

230Vac 50Hz

Electrical protection

Class II - IP20
Option: insulation clip for IP21 protection

Pilot wire Input (French market)

6 orders Pilot Wire by phase (L)

Output
Maximum Load

Relay 16Amps 250VAC
Up to 16A - 250Vac 50Hz (2 wires L,N)

Radio Frequency &
RF Receiving distance

868MHz < 10mW (Bidirectional communication)
Range of approximately 100m in open space.
Range of approximately 30m in residential environment.

Optional Floor Sensor

NTC 10kOhms at 25°C

Norms and homologation:

Your thermostat has been designed in
conformity with the following standards or
other normative documents:

EN 60730-1 : 2003
EN 61000-6-1 : 2002
EN 61000-6-3 : 2004
EN 61000-4-2 : 2001

EN300220-1/2
EN301489-1/3

R&TTE 1999/5/EC
Low voltage 2006/95/CE
EMC 2004/108/CE

RF Configuration button
Short press: Instantaneous RF transmission
3sec press: Thermostat or Central RF init.
5sec press: Slave receiver init.
15sec press: Reset of the receiver.

Status LED (RED/Green)
Green:
Fixed:

RF configuration

Flash:

RF reception

OFF:

Standby

Blink:

RF Alarm


Red:
Fixed:

Floor Limitation


Red/Green (Orange)
Fixed:
Pilot wire information.

Output LED (Red)
Red:

Heating demand

Blink:

Floor sensor error

GB