beautypg.com

Installation using a fixing bracket – Fenix ECOSUN S+ / S+ Anticor / Short User Manual

Page 6

background image






Installation using a fixing bracket

Attach the mounting frame so that the opening for the positioning screw is accessible. Slide one side of the panel onto the holder.

Slide the panel onto the other part of the holder and secure it with a screw.

Typ Spacing

Note

ECOSUN S+ 06

diameter of the opening in the brackets: 6 mm

when handling the panel, it is not advisable to

touch its radiant surface with dirty hands

ECOSUN S+ 08
ECOSUN S+ 09

40 x 1000

ECOSUN S+ 12
ECOSUN S+ 18

100 x 1000

ECOSUN S+ 24
ECOSUN S+ 30

200 x 1000

ECOSUN S+ 36

100 x 300

Spacing of grips at the back side of the panel:

After insertion, it is advisable to secure it in position with the use of

positioning screws to prevent it from sliding out.

Clearance distances from flammable objects:

from the radiant surface (temperature up to 380°C): 100 cm

from the top edge at the distance of the mounting brackets

from other parts of the panel: 25 cm

Lowest height above the floor: 350 cm (recommended value)

The mutual distance between panels is usually greater than the

height of their installation above the floor

The panel must not be placed directly under an electric socket.