Limiting range between two indexes

Proceed as in above mentioned section for maximum setting. Switch off the unit. Release
convector from mounting bracket.Release second latch from thermostat control knob. Turn
and place the knob on the desired minimum index. Correctly screw latch in the hole
located left from index"F". The knob should turn freely between two limit temperatures.

Locking rotation on index

Switch off the unit. Release unit from mounting bracket. Release one latch. Turn and place
knob precisely on the desired index.Correctly screw the latch in the hole indicated by
index"F". The knob should be blocked.

Calibration

To achieve trouble-free temperature control,the appliance must be set as described below.
With the doors and windows closed, arrange thermometer in the centre of the room 1,2m
above the floor. Set the on/off switch to position"M". Set the thermostat control knob to
the maximum position. As soon as the required room temperature is reached, for example
the thermometer indicates 20°C, slowly turn back the thermostat control knob until the
indicator light goes off. After the temperature has been set the thermostat will automatically
keeps the room temperature constant by successively switching on and off the power
supply to the unit.

Switch off

To switch off the convector without acting on the thermostat setting set the on/ off switch
to position"A".

Removing unit

Before removing the unit from its mounting bracket set the on/ off switch to position"A". If
an external pilot wire is used cut off its power supply too. Use screwdriver to release
locking parts. Disconnect the power supply cable from the wall junction box. Lift the unit
vertically to clear it from the bracket.

Notice

Only qualified, approved personnel are authorized to work on convector. The installation
must be disconnected from the power supply before starting any work. If the installation is
programmed by pilot wire,be sure to cut off the power supply to the concerned unit(s) and
pilot wire before starting work. Because the natural marble is a delicate material, it si
necessary to be carefull during the transport, manipulation and montage.

Economical operation

Switch off the power supply to your heating units,on/off switch to position"A"when you
ventilating your rooms for any lengthy period of time. Whenever you do not use a room
(guest room) or if you do not use your home for any extended period of time (vacation)
set the thermostat knob to the position *. The room temperature will then be automatically
kept on value approximately 7°C.

Important safety instructions

Do not cover your heating unit in any way. The"DO NOT COVER"warning tag is there to
remind you that any material covering the unit can catch fire. Never place or hang any

Electric installation

Convector is equipped by 3 conductors power supply cable (A05VVF) .
Power supply - 1/ N 230V / 50Hz
Colour indication of wires:
Phase - brown
Neutral - blue
Pilot wire - black

The power supply cable is connected to the wall
junction box.(Picture No.6). If not used, the pilot wire
must be connected to a potential free terminal in the
wall junction box. The power supply cable can only
be replaced by the manufacturer or an approved services company,as specific tools are
required.

Connection of pilot wire

The convector will operate according to the signals given
by the programmation device.
Tablet of signals.

Control

Description (Picture No.7).

ON/ OFF switch
Position"A" - heating off
Position"M" - heating on
A thermostat control knob,continuously variable setting
range from position * to position 9.

Heating indicator light

Limiting or blocking the
thermostat knob. (Picture No.8)

There are detachable latches in the holes of thermostat
control knob,which are used to limit thermostat control
knob set point or is possible to limit knob between two
set points. (Setting a temperature range).

Limitation to a maximum temperature

Switch off the unit.Release convector from mounting bracket.Release one latch. Turn the thermostat
control knob precisely on the desired maximum temperature. Correctly screw latch in the hole
indicated by the index"M". Return the knob to the position *. The knob should turn freely.

napájecí kabel

připojovací

krabice

závěsný rám

pict. 6

4

5

3

M

A

F

M

pict. 8

A M

5

6

7

8

9

pict. 7

mounting bracket

wall juction

box

power supply cable

Comfort

Eco

0

0

Mode

Signal