9

3

2

4

7

6

1

If faucet leaks from under handle:

Remove handle and ensure cap (1) is tight.
If leak persists–SHUT OFF WATER

SUPPLIES. Replace Ball Assembly

(2)–Repair Kit RP70 and Cam & Packing

(3)–Repair Kit RP61.
If faucet leaks from spout outlet:

SHUT OFF WATER SUPPLIES. Replace

Ball Assembly (2)–Repair Kit RP70 and

Seats & Springs (4)–Repair Kit RP4993.
If faucet exhibits very low flow

A. Remove and clean Aerator (5), or

B. SHUT OFF WATER SUPPLIES. Clean

Seats and Springs (4) of any debris.
If spray attachment does not

function properly:

SHUT OFF WATER SUPPLIES. Remove

Diverter Assembly (6) and clean.
If condition persists–SHUT OFF WATER

SUPPLIES. Replace Diverter Assembly

(6)–Repair Kit RP320.
If faucet leaks from base of spout:

SHUT OFF WATER SUPPLIES. Remove

spout and replace Spout O-Rings (7)–Repair

Kit RP25.

1/8" (3.18mm)

5

Maintenance

Cleaning and Care

Care should be given to the cleaning

of this product. Although its finish is

extremely durable, it can be damaged

by harsh abrasives or polish. To clean,

simply wipe gently with a damp cloth

and blot dry with a soft towel.