Cabling and Amplifier Selection
The EMS Series products are designed to be used with professional power amplifiers providing the following power
outputs:
EMS-81
500W/channel into eight ohms
EMS-121 700W/channel
into eight ohms
EMS-152 1200W/channel into eight ohms
EMS-215 1600W/channel
into four ohms
It is good practice to use an amplifier equal to the program power rating of the loudspeaker – so as to retain
sufficient headroom and good dynamic range. Care should be taken during operation to avoid amplifier clipping –
as this can cause serious damage to your loudspeakers. If in doubt, please contact your dealer who will be happy
to assist you in correct amplifier choice and setup.
Cabling
All EMS Series products are supplied with Neutrik Speakon
TM
NL4 connectors, wired pin 1+/1-. It is recommended
that the resistance of your cable is less than one tenth of the nominal system impedance. Given below are the
recommended maximum cable lengths for different cross-sections and impedances.
Conductor Cross Sectional Area
Maximum Recommended Cable Length
4 ohms
8 ohms
16 ohms
1.0mm
2
11m
22m
44m
1.5mm
2
17m
34m
68m
2.0mm
2
22m
44m
88m
2.5mm
2
29m
58m
116m
4.0mm
2
44m
88m
176m
6.0mm
2
66m
132m
264m
A small power amplifier working too hard is more likely to damage a loudspeaker than a large power amplifier