beautypg.com

Instruction on mounting and use gb – ELICA CLOUD NINE User Manual

Page 12

background image

1 2

Use

The cooker hood is provided with an upper air exit B for

discharging fumes externally for models including chimney

flue C ( Suction Version A- exhaust pipe not supplied).

If cooking fumes and vapours cannot be externally discharged,

the cooker hood can be used in the recirculating version

F: the installation of 1 active charcoal filter F allows the

recirculation of fumes and vapours through the upper grid G.

Electrical connection

Operation

INSTRUCTION ON MOUNTING AND USE

GB

Check also the drawings on the initial pages with the alphabetical

and numerical references in the explanatory text.

Closely follow the instructions in this manual. We cannot

accept liability for any faults, detriment or fire damage to the

appliance due to non-compliance with the manual’s

instructions. Installation and electrical connections must be

executed by a qualified technician. You should affix the hood

to a wall of sufficient weight-bearing capacity, so not to one

made of plasterboard. Do not install it inside a cupboard.

Make sure that there is a power socket near the hood and

that the system has a 30 mA differential. The mains voltage

must be the same as that on the label inside the hood. The

hood has a 1250 mm power cable with or without plug: if it

does have a plug, connect the hood to an accessible

approved socket; or if it does not (connection direct to the

mains), fit an approved bipolar switch with a minimum

contact opening of no less than 3 mm (accessible). This

installation and electrical connection must be executed by a

qualified technician.

Use the high suction speed in cases of concentrated kitchen

vapours. It is recommended that the cooker hood suction is

switched on for 5 minutes prior to cooking and to leave in

operation during cooking and for another 15 minutes

approximately after terminating cooking.

For the correct use please carefully read the intructions below.

Hood in stand-by: LED LIGHT SWITCHED OFF

1st suction speed (power) -GREEN LED LIGHT

2nd suction speed (power) . ORANGE LED LIGHT (amber)

3rd suction speed (power) - RED LED LIGHT

4th suction speed (power) - RED LED LIGHT (FLASHING)

Note: The 4th suction speed (power) stays on for 5 minutes,

after which the suction motor will position itself on the 2nd

speed.

Grease filters need cleaning: FLASHING GREEN LED light

(read instructions found under .Reset and configuration for

filter saturation signal.)

Coal filters must be cleaned or replaced: FLASHING

ORANGE (amber) LED light (read instructions found under

.Reset and configuration for filter saturation signal.)

Using the remote control

The remote control is able to control all the functions of the

hood:

Select the suction speed (power)

Control the central light

Control the lateral lights

Reset e configure the saturation of the filters signal

Selecting the suction speed (power):

Press the „ “ key or the „ “ key until you see the symbol

relating to the .Select the suction speed (power). function.

Press the .+. key or the .-. key or the „ “ key respectively to

increase or diminish or switch off (stand-by) the speed

(suction power).

Controlling the central light:

Press the „ “ key or the „ “ key until seeing the symbol

relating to the .Controlling the central light. function on the

remote control.

The central light can be switched on and off in two ways:

1. Press the .+. key or the .-. key respectively to switch the

central light (ON) or (OFF).

2. Press the „ “ key to change the state of the light from

(OFF) to (ON) or vice versa.

Controlling the lateral lights:

Press the „ “ key or the „ “ key until seeing the symbol

relating to the .Controlling the lateral lights. function on the

remote control.
Press the „ “ key to change the state of the lateral lights from
(OFF) to (ON) at maximum intensity and viceversa.

Press the .-. key to diminish the intensity of the lateral lights

until switching them off.

Press the .+. key to increase the intensity of the lateral lights.

Resetting and configuring the saturation of the filters

signal

Switch the hood on at any speed (see paragraph above

.Selecting the suction speed (power.).

Press the „ “ key or the „ “ key until seeing the symbol

relating to the .Resetting and configuration of the saturation of

the filters signal. function on the remote control.

Resetting the anti-fat filter saturation signal (GREEN LED

FLASHING on the control bar)

First proceed with the maintenance of the filter as

described in the corresponding paragraph.

Press the .+. and .-. keys contemporaneously for about 3

seconds. The LED stops flashing, indicating that the resetting

of the signal has been accomplished.

Resetting the carbon filter saturation signal (ORANGE

(amber) LED FLASHING)

Note! The reset of the carbon filter saturation signal is

normally deactivated. To activate it, see under paragraph

.Activating the carbon filter saturation signal..

First proceed with the maintenance of the filter as

described in the corresponding paragraph.

Press the .+. and .-. keys contemporaneously for about 3

seconds. The LED stops flashing, indicating that the resetting

of the signal has been accomplished.

Deactivating the carbon filter saturation signal (for

special applications)

Switch the hood off (see paragraph above .Selecting the

suction speed (power).).

Press the „ “ key or the „ “ key until seeing the symbol

relating to the .Resetting and configuration of the filters

saturation signal. function on the remote control.

Press keys .+. and .-. contemporaneously for about 3

seconds. The LED flashes in GREEN to indicate that the

carbon filter saturation signal has been deactivated.

To reactivate the carbon filter saturation signal, repeat the

operation. The LED flashes in ORANGE.

Maintenance of the remote control

Cleaning the remote control:

Clean the remote control with a damp cloth and a neutral

solution of detergent without abrasive substances.

Changing the battery:

. Open the battery casing using a small screwdriver with a

flat point.

. Change the finished battery with a new one of 12 V type

MN21/23

In inserting the new battery respect the polarity indicated

on the battery casing!
. Close the battery casing up again.