between the faders will flash each channel to full output regardless of the setting of the
crossfader or the master. The red blackout switch will black out all channels when
activated (down) and will override all other controls.
The CM-TS has a timer to allow a linear timed crossfade up to 2 minutes 40 seconds.
When the timer is set to zero (counter-clockwise) the crossfade follows the X-Y
crossfader. When a delayed crossfade is set, the crossfade progress will lag behind
the X-Y crossfader. If the timer is set fully clock-wise and the X-Y crossfader is pushed
quickly from scene X to scene Y, then a straight, smooth linear crossfade will be
completed in 2 minutes and 40 seconds. The crossfade can be stopped or reversed at
any time by moving the X-Y crossfader. The timed crossfade can be speeded up or
slowed down at any time by readjusting the timer control. The master is not affected by
the timer in the Y scene but is affected by the timer in the X scene. Therefore, a timed
master fade-up or down is possible in the X scene. The green LED light is the power
indicator. The LED indicators next to the X-Y crossfader track the crossfade. When
the top LED is bright and the bottom LED is off, the X scene is active. During a
crossfade, one LED will become dim while the other becomes bright. The master
control will fade both LED's just as it does the channels.
The CM-TS has a footswitch option which plugs into the accessory jack in the back and
allows remote crossfades and remote blackouts. The crossfader must be in Scene X
(up) in order for the footswitch to work. The left switch is the crossfade and the right is
the blackout. The crossfade timer is fully functional with this accessory.
The CM-TS controllers can be slaved together in a daisy-chain to control 12 or more
channels. Two or more controllers are connected together at the accessory jacks. The
first controller becomes the master with its master and X-Y crossfader controlling all the
slaves in the chain. The slave units' masters and X-Y crossfaders are inactive but the
timers are all independently functional. Call the factory for more information on
master/slave arrangement.
The control connector is wired so that the pin number is the channel number. Pin 15 is
common, pin 13 is +15 and pin 14 is -15 volts. The controller requires + and - 15 volts
from the dimmer or an optional AC power supply. The output voltage is adjustable from
5 to 12 volts. The low end is not adjustable. Output voltage is factory set to 0 to +10
volts.
ELECTRICAL SAFETY
1. KNOW YOUR EQUIPMENT
Read the owners manual carefully. Learn its applications and limitations as well as the
specific potential hazards associated with the product.