Set up ez3400 / ez3600, Menu 2, Menu – Digi-Star Analog Output 4 – 20mA User Manual
Page 7

Installation
D3708-GB Rev E Analog Output User/Installer Manual
4
1. Repeatedly press until the display
shows “menu”.
2. Press and hold for 3 seconds to enter
the menu.
3. Repeatedly press until the display
shows “menu 2”.
4. Press to enter menu 2.
5. Repeatedly press until the display
shows the required setting.
a. Use to set “ZEROUT”
to
0.
b. Use and to enter a
new value for
””
LOW WT”
and
”HIGHWT”.
c. Use to change the ””Anaout”
setting.
6. Press to confirm setting and advance
to next setting.
7. After all settings have been made repeatedly
press until you exit the menu and
return to weighing mode.
Set up EZ3400 / EZ3600
1. Enter desired “direct access number** and
press to select the desired setting.
d. Use to set “ZEROUT”
to
0.
e. Use and to enter a
new value for
””
LOW WT”
and
”HIGHWT”.
f. Use to change the ””Anaout”
setting.
2. Press to confirm setting and return to
weighing mode.
3. Repeat steps for the other settings.
**See page 3 for “direct access numbers
MENU 2