Connect load cell and j-box cable, Installing wires into terminal block – Digi-Star John Deere 1990 CCS Single Rank 30/36/40/44 User Manual
Page 7

Junction Box Mounting
D3864-US-Rev A
John Deere Planter Scale
5
JUNCTION BOX MOUNTING
The junction box is water resistant, not water-proof. It should be mounted to avoid submersion during wet
weather and to avoid physical abuse. The junction box can be mounted on the front or rear of the drill, planter
or seeder. All load cell cables must reach the J-Box. Install by removing the double sided tape backing and
apply to cleaned surface.
Connect Load Cell and J-Box Cable
1. Route front and rear load cell cables to J-box location.
Make sure they are not bound or pinched. Cable tie
(customer provided) load cell cables in place.
2. Insert load cell and J-box cables through each of the
water-tight strain-reliefs.
3. Remove each terminal block from the J-box.
4. Connect wires of the same color to the same terminal
block. See instructions below.
5. Install terminal block into the J-box as shown (location
not important).
6. Tighten nuts on the water-tight strain-reliefs.
7. Assure that gasket is properly installed in the cover.
8. Attach cover using 4 screws (provided).
Installing wires into Terminal Block
1. Open levers 90º to locked position.
2. Insert individual wires into terminal.
3. Close lever.
4. Tug wire to assure solid connection.
Note: Wire strip length is 7/16” (11mm).
406232 J-Box Lever Nut 4Pt (Planter)
141837 Cable - 30Ft J-Box
406074 Cable - 45Ft J-Box
403335 Cable - Power 17Ft 2-Wire
406073 Cable - Power 36Ft 2-Wire
406072 Cable - Power 6Ft 2-Wire
824316 Cable - 15FT-J-Box
145096 Cable - 70FT-J-Box
406276 Cable – Power 65FT 2-Wire