Digi-Star EZ 3200/EZ 3200V Short Manual User Manual
Page 2

BRIEF PROGRAMMING MANUAL EZ 3200/EZ3200V WEIGHING SCALE
24-4-2003 Art. Nr. A5910660 - GB
Page 2/2
9
TO DELETE A RECIPE (completely delete a programmed recipe)
9.1
Press and hold Recipe and then press On. The scale displays progrm.
9.2
Press Recipe until the recipe to be deleted is displayed.
9.3
Press and hold Zero and then press On to delete this recipe. A running text with instructions shows that
the old recipe can be printed.
9.4
Press Zero to delete this recipe. The scale displays recipe erased, followed by the next recipe.
9.5
Repeat steps 9.2 thru 9.4 until all recipes have been deleted.
9.6
Press Net/Gross to return to normal weighing mode.
2
10
TO LOAD A BATCH USING A RECIPE
10.1 Press Recipe until the required recipe number is displayed.
10.2 Press Load/Unload. The scale displays the number of animals or the programmed amount.
10.3 a) Press Load/Unload to confirm this number of animals and the programmed amount.
b) To edit the number of animals or the amount, press Clear and enter the new values using the numerical
keypad.
10.4 Press Load/Unload. The scale displays the calculated amount of the first ingredient.
10.5 Depending on the presetting the next ingredient will appear automatically or after Ingr/Accum has been
pressed.
10.6 Once all ingredients have been loaded, the scale displays: recipe completed total = xxx kg.
2
11
TO REVIEW A RECIPE (to check a recipe)
11.1 Press Recipe. The scale displays the first recipe loaded in memory.
11.2 Press Recipe until the required recipe number is displayed.
11.3 Press Ingr/Accum. The scale displays all ingredients of the recipe. At the end it displays the totally
programmed amount, total = xxxx kg.
11.4 Press Net/Gross to return to normal weighing mode.
2
12
TO REVIEW INGREDIENT ACCUMULATION
12.1 Press Ingr/Accum. The scale displays the first recipe and the total amount that has been dosed in since
the last time this ingredient was deleted (see manual, page 30).
12.2 Press Ingr/Accum until all ingredients have been displayed.
12.3 Press Net/Gross to return to normal weighing mode.
For a more detailed description, see manual EZ 3200 / 3200V
1
Getting started
Page 8, 9
2
To zero balance the scale
Page 9
3
To change the language
- Press Net/Gross + On.
- Press Select to select to menu 1 and press On.
- Press Select until the required language is displayed: Englsh / Nederl /
Francs / Deutsh / Italan / Port / Espanl / Vesta / Magiar / Dansk.
- Press On to confirm the selected language.
4
To change the entry
method
Pages 18, 20 1 = Amount per Animal 2 = Percent % 3 = KG. Amount per
Load
5
To change the tolerance
Page 24 (to change the tolerance) and page 25 (to change the delay time).
6
To rename ingredients
Pages 37, 29
7
To program a new recipe
Page 19 and for examples, pages 38, 39, 40.
8
To edit a recipe
Page 21
9
To delete a recipe
Page 22
10
To load a batch using a
recipe
Pages 25, 26
Attention: (for Triomix Triomix s and Gigant set delay time to MANUAL)
1 Enter 443 using the numerical keypad.
2 Press Select. The scale displays DELAY followed by 5.
3 Press Select until MANUAL is displayed.
4 Press On to confirm the setting.
11
To review a recipe
Page 27
12
To review ingredient
accumulation
Page 28