Indicator Mounting

6

Case IH Planter Scale

D3893-US Rev A

INDICATOR MOUNTING

The scale indicator can be mounted in the tractor cab or on the planter with swivel mounting pack (406983).

Depending on which kit you purchase, two cables must be connected to the indicator bottom panel, J-Box and

power cables. Refer to Indicator Manual D3831-US for details of indicator mounting options and connection of

power cord.

1. Bolt the readout in the cab, or mount the swivel bracket on the drill, planter or seeder.

2. Install power cord to a 12-volt negative ground battery.

3. Route J-box cable to indicator and install to indicator bottom panel.

4. Program indicator with set-up #145023 and calibration #22500 (see Indicator Manual).

Power Connection:

The power cable should be connected directly to a vehicle battery or regulated power supply. The scale end of

the power cable is attached to the J901 connector located on the bottom panel of the indicator.

Connect the RED wire from the power cable to +12 VDC and the BLACK wire to GROUND. The indicator is

fused internally at 4 amps.

Power Cable Connections:

Wire color Wire Function

Red

Battery (+12 VDC)

Black

GROUND

Load Cell Connection:

The indicator is designed to operate with strain gage load cells. The indicator will normally be supplied with a

“J-BOX” cable going between the scale and the load cell junction box. Extension kits are available from your

dealer in various lengths.

Load Cell Wire Digi-Star Function

1 RED

+EX

2 GREEN

-SIG

3 WHITE

+SIG

4 BLACK

-EX

5 CLEAR

SHIELD

INDICATOR MOUNTINGS