Digi-Star ST 3400 User Manual
Page 30
Menus and Calibration
SETTING
[display]
D.A.N
NO.
OPTIONS [displayed]
BOLD=DEFAULT
DESCRIPTION
DATE FORMAT
(date f)
203
1-mm-dd
2-mm/dd/yy
3-mm/dd/yyyy
4-dd-mm
5-dd/mm/yy
6-dd/mm/yyyy
7-ddmoyy
8-ddmoyyyy.
Select date format.
DATE
(date)
204
Enter XXXXXX
Select key changes
date -function key
chooses mm/dd/yy .
ONE LINE PRINT
(Il prt)
212
ON/OFF
If ON -indicator data will
be printed on one line.
PRINT FORMAT
(prtfmt)
216
PRTST1 (1 line print)
PRTST3 (3 line print)
Select print format.
Refer to EZIII Technical
Manual for more
options.
ZERO OUTPUT
(zerout)
219
Perform the
Zero/Balance for the
SCOREM #11 weight
output and the analog
output (4-20mA).
ANALOG LOW
WEIGHT
(LOW WT)
241
Enter analog weight
value to equal 4mA or 0
volts.
ANALOG HIGH
WEIGHT
(HIGHWT)
242
Enter analog weight
value to equal 20mA or
5 volts.
ANALOG SELECT
(ANAOUT)
243
Select 0-5V,4-20mA or
0-20mA output.
MENU 3. SCALE CALIBRATION SETTINGS
DISPLAY COUNT
(count)
301
.01,.02,.05,.1,.2,.5,1,2,5,10,
20, 50,100
Select display count
size of weigh values.
DISPLAY UNIT
(lb-kg)
303
LB/KG
Display pounds -lb or
kilograms -kg
CAPACITY
(cap)
304
40000
Enter MAXIMUM weight
measurable on scale.
26
ST3400 User’s Manual
D3943 Rev C