Digi-Star ST 3400 User Manual

Page 30

background image

Menus and Calibration

SETTING

[display]

D.A.N

NO.

OPTIONS [displayed]

BOLD=DEFAULT

DESCRIPTION

DATE FORMAT

(date f)

203

1-mm-dd
2-mm/dd/yy
3-mm/dd/yyyy
4-dd-mm
5-dd/mm/yy
6-dd/mm/yyyy
7-ddmoyy
8-ddmoyyyy.

Select date format.

DATE

(date)

204

Enter XXXXXX

Select key changes
date -function key
chooses mm/dd/yy .

ONE LINE PRINT

(Il prt)

212

ON/OFF

If ON -indicator data will
be printed on one line.

PRINT FORMAT

(prtfmt)

216

PRTST1 (1 line print)
PRTST3 (3 line print)

Select print format.
Refer to EZIII Technical
Manual for more
options.

ZERO OUTPUT

(zerout)

219

Perform the
Zero/Balance for the
SCOREM #11 weight
output and the analog
output (4-20mA).

ANALOG LOW
WEIGHT

(LOW WT)

241

Enter analog weight
value to equal 4mA or 0
volts.

ANALOG HIGH
WEIGHT

(HIGHWT)

242

Enter analog weight
value to equal 20mA or
5 volts.

ANALOG SELECT

(ANAOUT)

243

Select 0-5V,4-20mA or
0-20mA output.

MENU 3. SCALE CALIBRATION SETTINGS

DISPLAY COUNT

(count)

301

.01,.02,.05,.1,.2,.5,1,2,5,10,
20, 50,100

Select display count
size of weigh values.

DISPLAY UNIT

(lb-kg)

303

LB/KG

Display pounds -lb or
kilograms -kg

CAPACITY

(cap)

304

40000

Enter MAXIMUM weight
measurable on scale.

26

ST3400 User’s Manual

D3943 Rev C