Troubleshooting – DeLonghi PACA110-A120E User Manual
Page 16
16
Troubleshooting
PROBLEM CAUSE
REMEDY
The air conditioning
unit does not start.
•
No electricity.
•
It is not plugged into the socket.
•
The safety device of the plug has tripped.
•
The internal safety device has tripped.
•
Restore electricity.
•
Plug into the socket.
•
Reset the safety plug.
•
Wait 30 minutes, if the problem
persists, contact your service
center.
The air conditioning
unit works for a
short time only.
•
The air exhaust hose has a constriction.
•
The air exhaust hose is blocked.
•
There are tight bends in the air exhaust hose.
•
Position the exhaust hose cor-
rectly.
•
Check there are no obstacles
Obstructing air discharge.
•
Eliminate the tight bends.
The air conditioner
works, but does not
cool the room.
•
Window open.
•
There are heat sources in the room (lamps,
etc.).
•
The exhaust hose is detached.
•
Air filters clogged.
•
Close the window.
•
Eliminate the heat source.
•
Connect the exhaust hose.
•
Clean or replace the filters.
•
Clean or replace the filter.
Bad odour in the
room.
•
The filter is clogged.
The air conditioner
does not operate
for about 3 minutes
after turning it on.
•
The internal compressor safety device pre-
vents the appliance from being restarted
until three minutes have elapsed since it was
last turned off.
•
Wait. This delay is part of nor-
mal operation.
/
/
PP FF
/
/ appears
on the display.
•
The appliance has a self diagnosis system to
identify a number of malfunctions.
•
See the self-diagnosis chapter.