6. If the refrigerator fails to work on 230/ 240 V, check:

Ÿ That the 230 V supply is connected to the

refrigerator.

Ÿ That the fuse is intact.
If the refrigerator is not cold enough it may be

because:
1. The ventilation is inadequate owing to reduced area

of the ventilation passages (partial blockage of

grilles from wire mesh etc).

2. The evaporator is frosted up.

3. The temperature control setting is incorrect.

4. The gas pressure is incorrect - check the pressure

regulator at the gas container.

5. The ambient temperature is too high.

6. To much food is loaded at one time.

7. The door is not properly closed or the magnetic

sealing strip is defective.

8. More than one source of energy is used at the

same time. If the refrigerator still does not work

properly, call a service technician.

The sealed cooling system must not be ope-

ned, since it contains corroding chemicals

under high presurre.

MAINTENANCE

Inspect the gas hose periodically for cracks or deep

chafing marks. Connections can be tested for leaks

using a soap solution. Do not use a naked flame! If

there is any suspicion of damage, call for a service

technician. The cooling unit behind the refrigerator

should be cleaned with a brush from time to time, but

make sure that the refrigerator is switched off when

doing this. We recommend that a service technician

check the refrigerator once a year.

SOME USEFUL HINTS

Make sure that:

Ÿ The refrigerator is not operating on 12 V when the

vehicle is parked, otherwise you will drain the car

battery in a short time.

Ÿ Defrosting is carried out periodically.

Ÿ The refrigerator is left with the door(s) ajar when it

is not to be used for some time.

Ÿ Liquids or items with a strong odour are well

packaged.

Ÿ The ventilation openings are unobstructed.

Ÿ The door is secured by means of the travel catch

when the caravan is on the move.

Ÿ Only one mode of operation at a time is used to

run the refrigerator.

GUARANTEE AND SERVICE

Warranty arrangements are in accordance with EC

Directive 44/1999/CE and the normal conditions appli-

cable for the country concerned. For warranty or other

servicing, please contact our Dometic Service depart-

ment. Any damage due to improper use is not covered

by the warranty. The warranty does not cover any

modifications to the appliance or the use of non-origi-

nal Dometic parts; the warranty does not apply if the

installation and operating instructions are not adhe-

red to and no liability shall be entertained. Parts can

be ordered throughout Europe from our Dometic

Service department. Your Service Centre contact

numbers are found in the “European Service

Network” booklet. When contacting Dometic Service,

please state the model and product number, serial

number and MLC, if applicable. You will find this

information on the data plate inside the refrigerator

.

TECHNICAL DATA

Overall dimensions, refrigerator

Height

826 mm

Width

486 mm

Depth (incl. cooling unit)

without door

498 mm

with door

610 mm

Build-in dimensions

Height

830 mm

Width

490 mm

Depth

510 mm

Capacity

gross

103 lit.

net

98 lit.

frozen food compt

6,5 lit.

Weight (without packaging)

28 kg

Electrical data

Input

230 V

135 Watt

12 V

130 Watt

Energy consumption /24 h

2,1 kWh

LP gas data

Input

252 Watt

Energy consumption /24 h

0,27 kg

Cooling medium Ammonia (R 717)

LP GAS CONNECTION

The refrigerator is designed for operation on LP gas

of Butane or Propane.The refrigerator is not designed

for operation on town gas or natural gas.

The gas installation should only be carried out by a

person experienced in gas fitting. It is recommended

that the gas pipe feeding the refrigerator is run

underneath the caravan and is so arranged that it is

possible to turn off the supply to all appliances inclu-

ding the refrigerator

when they are not required. The supply pipe should

preferably be of copper. If any other material is used,

it must be of a type approved for use with conti-

nuously operating bottled- gas appliances, and have

threaded compression connections throughout.

PUSH-ON CONNECTIONS MUSTNOT BE USED

(We do not recommend the use of “rubber” type

flexible tubing for connecting permanently operating

appliances of this type in the United Kingdom). All

connectors etc. should be of a type specifically desi