beautypg.com

Pre-installation preparation – Desa KC42N User Manual

Page 6

background image

www.desatech.com

116239-01F

6

• When locating termination cap, it is important

to observe the minimum clearances shown in

Figure 7, page 8.

• If recessing into a wall, you can avoid extra

framing by positioning your fireplace against

an already existing framing member.

• Do not recess termination cap into a wall or

siding.

• You may paint the termination cap with 450º F

(232º C) heat-resistant paint to coordinate with

the exterior finish.

• There must not be any obstruction such as

bushes, garden sheds, fences, decks or util-

ity buildings within 24" from the front of the

termination cap.

• Do not locate termination cap where excessive

snow or ice build up may occur. Be sure to

clear vent termination area after snow falls to

prevent accidental blockage of venting system.

When using snow blowers, do not direct snow

towards vent termination area.

• For horizontal installations above 2,000 feet, it

is recommended that a 12" extension pipe be

added before starter elbow and a round hori-

zontal termination be used (see High Altitude

Installation, page 17).

CLEARANCES

Minimum clearances to combustibles for the fire-

place are as follows:

*Back and sides

0"

Perpendicular walls

6"

Floor

0"

Ceiling to louver opening

42"

Front

36"

Top of Standoffs

0"

Vent

( S e e v e n t i n g

instructions for

specific venting

clearances.)

Combustible material with a maximum thick-

ness of 5/8" may be flush with the top front of

fireplace.

* For back and sides of fireplace, do not pack

with insulation or other materials. Zero inch

clearance to combustible materials are for fram-

ing purpose only.

PRE-INSTALLATION

PREPARATION

Continued

NOTICE: This fireplace is in-

tended for use as supplemental

heat. Use this fireplace along

with your primary heating sys-

tem. Do not install this fireplace

as your primary heat source.

If you have a central heating

system, you may run system’s

circulating blower while using

fireplace. This will help circulate

the heat throughout the house.

In the event of a power outage,

you can use this fireplace as a

heat source.

FRAMING AND FINISHING

Figure 4 shows typical framing of this fireplace.

Figure 5 shows framing for corner installation. All

minimum clearances must be met.

For available accessories for this fireplace, see

Accessories on page 42. If you are using a sepa-

rate combustible mantel piece, refer to Figure 6

for proper installation height. You can install

noncombustible mantels at any height above the

fireplace.
Note:

Noncombustible mantels may discolor!

Figure 4 - Framing Clearances for

Installation Against an Exterior Wall

40

1

/

8

"

48

1

/

4

"

23" Horizontal Vent
26

1

/

2

" Vertical Vent

This manual is related to the following products: