beautypg.com

Delta OILLUBE AIR COMPRESSOR DLKC6580V2 User Manual

Page 24

background image

24-ENG

D25235

PROBLEM

CAUSE

CORRECTION

Motor will not
run.

Fuse blown, circuit breaker
tripped.

1.

Check fuse box for blown
fuse and replace as nec-
essary. Reset circuit
breaker. Do not use a fuse
or circuit breaker with
higher rating than that
specified for your particu-
lar branch circuit.

2.

Check for proper fuse. You
should use a time delay
fuse.

3.

Check for low voltage
conditions and/or proper
extension cord.

4.

Disconnect the other elec-
trical appliances from cir-
cuit or operate the com-
pressor on its own branch
circuit.

Motor overload protection
switch has tripped.

Let motor cool off and over-
load switch will automatically
reset.

Tank pressure exceeds
pressure switch "cut-in"
pressure.

Motor will start automatically
when tank pressure drops
below "cut-in" pressure of
pressure switch.

Loose electrical connec-
tions.

Check wiring connection
inside pressure switch and ter-
minal box area.

Have checked by a Trained
Service Technician.

Check valve stuck open.

Remove and clean, or replace.

Possible defective motor
or starting capacitor.

Have checked by a Trained
Service Technician. Do not
operate the compressor in the
paint spray area. See flamma-
ble vapor warning.

Paint spray on internal
motor parts.

Bleed the line by pushing the
lever on the pressure switch to
the "off" position; if the valve
does not open, replace switch.

Pressure release valve on
pressure switch has not
unloaded head pressure.

This manual is related to the following products: