beautypg.com

Caution, Malfunctions / troubleshooting, Decommissioning – Dimplex LA16ASR User Manual

Page 9

background image

9

CLEANING / MAINTENANCE

MALFUNCTIONS / TROUBLESHOOTING

DECOMMISSIONING

the supply and return line of the heat pump. The
regulations of the trade associations must be
adhered to. If in doubt, contact the manufacturers of
the chemicals!

To prevent consequential damage it

is imperative that the water circuit be neutralized
after cleaning using appropriate agents.

Caution - Heating Engineers

Depending on the water quality and quantity, in
particular in the case of mixed installations and
plastic pipes, mineral deposits (rust sludge, lime)
may form impairing the proper functioning of the
heating installation. A cause of this is the water
hardness as well as oxygen dissolved in the filling
water as well as additional oxygen from the air which
may penetrate via valves, fittings and plastic pipes
(oxygen diffusion). As a preventive measure it is
recommended that a physical water conditioner such
as ELYSATOR be used.

8.3

Cleaning of Air Side

Evaporator, fan and condensate drain should be
cleaned of debris (leaves, branches, etc.) from time
to time. To this end, the front panel of the heat pump
should be opened first at the bottom and then at the
top.

Prior to opening the unit it must be

ensured that all electrical circuits are disconnected
from the power source.

T h e r e m o v a l a n d r e i n s t a l l a t i o n o f t h e p a n e l
a s s e m b l i e s t o b e p e r f o r m e d a s d e s c r i b e d i n
Chapter 4.

When cleaning do not use any sharp or hard objects
so as to prevent any damage to the evaporator and
the condensate pan.

CAUTION!

CAUTION!

MALFUNCTIONS /
TROUBLESHOOTING

This heat pump is a quality product and is designed
for troublefree and maintenance-free operation. In
the event that a malfunction occurs nevertheless,
you will be able to correct the problem easily
yourself. Simply consult the Malfunctions and
Troubleshooting table in the operating manual of
the controller. Malfunctions can be interrogated at
the heat pump controller. If the problem cannot be
corrected by the user, please contact the after-sales
service in charge (see Warranty Card).

Any work on the heat pump may only

be performed by an authorized and qualified after-
sales service.

DECOMMISSIONING

10.1 Placing Out of Service in Summer

Placing the heat pump out of service in summer can
be effected by switching the heat pump controller to
the "Summer" operating mode.

10.2 End-of-Life Decommissioning /

Disposal

Before removing the heat pump, disconnect the
machine from the power supply and close all valves.
Environment-relevant requirements regarding the
recovery, recycling and disposal of service fuels and
c o m p o n e n t s i n a c c o r d a n c e w i t h a l l r e l e v a n t
standards must be adhered to. In this context,
particular attention must be paid to the proper
disposal of refrigerants and refrigeration oils.

9

10

CAUTION!