beautypg.com

Eng02.ai, Installer’s instructions – Cata 604 HVI User Manual

Page 10

background image

Installer’s Instructions

Installation

These Instructions are for the qualified

technician, as a guide to installation, adjustment

and maintenance, according to the laws and

standards in force. These operations must always

be carried out when the appliance has been

disconnected from the electric system.

Positioning

The appliance can be fitted into a working area

as illustrated on the figure 4. Apply the seal

supplied over the whole perimeter of the

working area.

Electrical connection

Prior to carrying out the electrical connection,

please ensure that:

- the plant charac- teristics are such as to

follow what is indicated on the matrix

plate placed at the bottom of the working

area;

- that the plant is fitted with an efficient

earth connection, following the standards

and law provisions in force. The earth

connection is compulsory in terms of the

law.

Should there be no cable and/or plug on the

equipment, use suitable absorption material for

the working temperature as well, as indicated on

the matrix plate. Under no circumstance must the

cable reach a temperature above 50°C of the

ambient temperature.

The manufacturers decline any responsibility in

the event of non-compliance with what is

described above and the accident prevention

norms not being respected and followed.

To avoid all risk, if the power cable becomes

damaged, it must only be replaced by the

manufacturer, by an authorised service centre,

or by a qualified electrician.

(Fig. 5)

*considering complementary factor

If once the appliance is installed there is access

to the lower part, a protection panel (wooden or

something similar) ought to be placed at the

distance indicated in the figure.

Insert in the fixed wiring a mean for disconnec-

tion from the supply mains having a contact sepa-

ration in all poles that provide full disconnection

under overvoltage category III conditions, in

accordance with the wiring rules. The plug or

omnipolar switch must be easily reached on the

installed equipment.

This appliance is not intended to be used via an

external timer or a remote control system.

This manual is related to the following products: