beautypg.com

Extractor hood – Cata TF 3600 User Manual

Page 8

background image

8

EXTRACTOR HOOD

Dear Customer,
Thank you for buying our hood. Please read these instructions carefully

for its optimum installation, use and maintenance.
Notes: The figures mentioned in this manual are in the first pages.
This hood is designed for fitting in a cabinet or on some other support.

Warning: consult local regulations regarding fumes outlets. Do not

connect the hood to a fume, ventilation or hot air duct. Confirm

that room ventilation is appropriate with the local authorities.

Make sure
the maximum air extraction flow rate for the appliances in the room

does not exceed 4 Pa (0.04 mbar).The room must have adequate

ventilation if an extractor hood is used simultaneously with appliances

that run on gas or other fuels. The evacuated air must be extracted

through ducts that are used for evacuating fumes from appliances that

run on gas or other fuels. Regulations regarding air extraction must be

complied with.
This product in intended for HOUSEHOLD USE only.
Use a rigid PVC pipe with a min. Ø l20 mm to evacuate fumes outside.
The above restrictions do not apply to hoods with no fumes outlet to

outside
(recirculation system with activated charcoal filter).
Install the hood in line with the indications on fig. 1.
For gas cooking appliances only: the minimum distance to the hood

must be at least 65 cm.
Warning: Failure to install the screws or fixing device in accordance
with these instructions may result in electrical hazards.
INSTALLATION
The cooker hood is supplied with

3 Spacer (F)

4 Screws (C)

2 Bulbs

To fixing the Hood, use the 4 screws (c) Ø6mm supplied with the hood.
Close the space that remains between the hood and the wall,

adjunsting the spacer (F).
Before completing any connection, make sure the house voltage

corresponds with the voltage indicate on the data label.

Connecting the hood to the grid
Warning: before connecting the hood: switch off the electricity

supply and check that the supplied voltage and frequency

coincide with that indicated on the appliance nameplate.
If the extractor hood has a plug, connect it to a power socket in line

with applicable regulations, located in an accessible area.
If the hood does not have a plug, connect it directly to the electrical

grid, protected by a separator device accessible for disconnection, in

line with local regulations.
The connection to the electrical mains must be made as follows:
BLUE………………………..”N” NEUTRAL
BROWN……………………..”L” LIVE
GREEN AND YELLOW……EARTH

If the terminals of the plug are unmarked or if you are in any doubt

consult a qualified electrician.
If it is not supplied fit a plug normalized in the cord for the load showed

on the rating plate.

USE OF THE HOOD – SAFETY
Warning:
the hood may stop working during an electrostatic

discharge (e. g. lightning). This involves no risk of damage. Switch

off the electricity supply to the hood and reconnect after one minute.
This appliance can be used by children aged from 8 years and above

and persons with reduced physical, sensory or mental capabilities or

lack of experience and knowledge if they have been given supervision

or instruction concerning use of the appliance in a safe way and

understand the hazards involved. Children shall not play with the

appliance. Cleaning and user maintenance shall not be made by

children without supervision.
To avoid the risk of fire, clean the metal filter regularly, permanently control

pans containing hot oil and do not flambé food underneath the hood.
Do not use the hood if it shows signs of damage or imperfection.

Contact an official distributor or authorised dealer.
Accessible parts may heat up when using cooking appliances.

AIR INTAKE SPEED (Fig 2)

1- Filter clean warning display/button. Warning of the need to replace the

filter – press to deactivate once the filter has been cleaned or replaced.

2- Enable and disable extractor fan timer.
3- Lighting on and off. Keep pressed down to adjust the lighting intensity.
4- Extractor fan on and off.
5- Extractor fan speed - button: speed 1, 2 and 3/4
Timer: the extractor fan works for 5 min. at the current speed and another 5
min. at each of the lower speeds until it stops.

SUCTION VERSION
If the hood is to be installed as a SUCTION hood, connect the plastic

outlet piece (A) supplied with the hood (125mm diameter pipe for

better performance and lower noise levels.

FILTERING VERSION (INTERNAL RE-CYCLING)
When there is no exhaust duct for venting out-door, you can use a

carbon filter (B). The air is depurate by the filter and put again in the

surrounding.
The air is released in the room through a connecting pipe, which goes

through the hanging cupboard and us connected to the connecting

ring supplied (A) Fig 1.

HOOD MAINTENANCE

Warning: always switch off the electricity supply before carrying

out maintenance work on the hood. In the event of a fault,

contact an official distributor or authorised dealer.

Exterior cleaning: use non-corrosive, liquid detergent and avoid the use

of abrasive cleaning products.
Grease filters: to avoid fires, clean thoroughly once a month or whenever

the display pilot light indicates as such. To do so, remove the filters and

wash with hot water and detergent. If using a dishwasher, position the

filters vertically to prevent solid remains from depositing on them.
Activated charcoal filters: replace the every 2 months.

Important: increase the filter cleaning/replacement frequency if

the hood is used for more than 2 hours a day. Always use genuine

filters from the manufacturer.

Bulb replacement (look for the

symbol in the figures)

Warning: do not handle

the bulbs until the electricity supply

has been switched off and they have cooled.

Important: use new bulbs according to that indicated on the hood

nameplate.

Use bulbs with an aluminium reflector to replace halogen bulbs. Do not

use dichroic bulbs - risk of overheating.

Legal information
The manufacturer:
- Declares that this product meets all basic requirements regarding low-

voltage electrical equipment established in Directive 2006/95/EC of

12 December 2006 and electro-magnetic compatibility established in

Directive 2004/108/EC of 15 December 2004.
- Is not responsible for any failure to observe the instructions given in

this manual and current safety regulations for the correct use of the

equipment.
- Reserves the right to make any modifications to the equipment or this

manual without prior notice.
Contact our official distributor should you require technical assistance

or additional information on our products.

EN

This manual is related to the following products: