Power, Read limits, Power read limits – PSC Falcon 5500 User Manual
Page 14

Configuration Settings
10
Falcon
®
5500 RFID Mobile Hybrid Computer
Power
1. Under
Decoding Properties
, go to
Configure >
RFID > Power
2. Enable/disable
Growing Power
by
selecting the checkbox. When dis-
abled, a constant level of RF power
is output when reading tags. When
enabled, the level of RF power starts
at a minimum level, and then
increases to a maximum level, where
it will remain for the duration of the
painting operation.
3. Set
Minimum/Maximum Read
using
the sliders.
•
Minimum Power:
The minimum RF power level to use for reading tags.
It only applies when
Growing Power
is enabled.
•
Maximum Power:
The maximum RF power level to use for reading tags.
If
Growing Power
is disabled, this is the power level used for the entire
painting operation.
Read Limits
1. Under
Decoding Properties
, go to
Configure >
RFID > Read Limits
•
Total Read Timeout:
The maxi-
mum amount of time spent per-
forming an entire painting
operation. If set to
Infinite,
painting will stop only when the
trigger is released, a
New Tag Time-
out
occurs, or the minimum
number of tags have been read.