Installation requirements, Electrical installation – Caple C761GSS User Manual
Page 3

3
Electrical Installation
This appliance must be connected by a
qualified electrician using fixed wiring via
a double pole isolating switch (fig. 1).
As the colours of the wires in the mains
lead for the appliance, may not corre-
spond with the coloured markings iden-
tifying the terminals in your spur box,
proceed as follows:
1) The wire which is coloured green
and yellow must be connected to
the terminal marked E (Earth)
or coloured Green.
2) The wire which is coloured blue must
be connected to the terminal marked
N (Neutral), or coloured Black.
3) The wire which is coloured brown
must be connected to the terminal
marked L (Live), or coloured Red.
FUSE
DOUBLE POLE SWITCHED
FUSED SPUR OUTLET
USE A 3 AMP FUSE
ON
Fig. 1
WARNING!
ELECTRICITY CAN BE
EXTREMELY DANGEROUS.
THIS APPLIANCE MUST BE EARTH-
ED.
Installation Requirements
Technical Information
Total absorbed power
11.25 kW
Double-ring burner
3.20 kW
Rapid burner (1)
3.05 kW
Rapid burner (2)
2.40 kW
Semi rapid burner
1.60 kW
Auxiliary burner
1.00 kW
Voltage
230 V Single phase
Cat.
I
2H - Class
3