Conversion to natural gas or to lpg, Injectors replacement of top burners – Caple CR9204 User Manual
Page 19

19
Conversion to Natural Gas or to LPG
Injectors replacement of
top burners
Every cooker is provided with a set of
injectors for the various types of gas.
Injectors not supplied can be obtained
from the After-Sales Service.
Select the injectors to be replaced
according to the table at page 21.
The nozzle diameters, expressed in
hundredths of a millimetre, are marked
on the body of each injector.
To replace the injectors proceed as fol-
lows:
– Remove the grids and extract the
burner bodies.
– Using a wrench, substitute the nozzle
injectors “J” (Figs. 3.4a, 3.4b, and
3.4c) with those most suitable for the
kind of gas for which it is to be used
(see “Table for the choice of the injec-
tors”).
The burners are constructed in such
a way so as not to require the regu-
lation of the primary air.
J
Fig. 3.4b
J
Fig. 3.4a
Auxiliary and
Semi-rapid
burner
Triple-ring
burner
DUAL burner
J
Injector for inner crown
J
Injectors for
outer crowns