beautypg.com

Ab c, Tension adjustment of the door spring, Connection of drain hoses – Caple Di614 User Manual

Page 23

background image

21

Tension adjustment

of the door spring

【Figure5】

Tension adjustment of the door spring

Connection of drain hoses

The door springs are set at the factory to the proper tension for the outer door. If aesthetic

wooden panel are installed, you will have to adjust the door spring tension. Rotate the adjusting

screw to drive the adjustor to strain or relax the steel cable(see figure 5).

relax

Drain pipe connection

【Figure6】

Adjust the door spring

tension until the door
remains balance in the

fully-opened position.

φ 40mm

A

B

C

Counter

Front

Drain pipe

Drain hose hook

Close the drain hose hook to the counter

NOTE

The top of the hose

must be at a height

between

40 and 100cm.

The free end of the

hose must not be

immersed in water.

Insert the drain hose into a drain pipe with a minimum diameter of 4cm, or let it

run into the sink, making sure to avoid bending or crimping it. Use the speical
plastic support that comes with the appliance (figure 6).The top of the hose must be at

a height between 40 and 100cm. The free end of the hose must not be immersed in
water to avoid the back flow of it. ATTENTION: The special plastic hose support must be

solidly fastened to the wall to prevent the drain hose from moving and allowing water
to spill outside the drain.