DDMEXT2

(fig. 1)

Warning! The peripheral exhausting group (remote fitted extraction motor) is built in class

II (symbol on the rating plate), therefore it must not be earthed.

The appliance is designed to exhaust fumes and odours very silently and in the best way. It

must be installed in the house and connected to the cookerhood, which is in the kitchen (fig.

2) or to the SCET control unit 1.

Types of installation: to make the installation easy, the appliance can be fixed on the wall,

on the ceiling or on the floor in a horizontal position (fig. 3 ) or vertically (fig. 4) to the fixing

level.

Note: in the vertical fixing, the brackets supplied can be used only on the longest side (fig. 6).

Installation of the appliance: after deciding the position and the type of installation, insert the

anti-vibration rubber caps in the holes of the brackets supplied (fig. 5C).

The rubber caps must be put on the sides which are in contact with the wall.

Put the brackets (fig. 5A) on the remote fitted extraction motor by matching its holes with those

of the brackets. Fix with the screws supplied (fig. 5B).

Put the group on the point previously chosen for the installation and mark the points on the wall

where the holes must be drilled.

Insert the dowels supplied in the holes (fig. 6A). Put the remote fitted extraction motor on the

wall by matching the holes of the brackets with the plastic dowels. Screw with the screws sup-

plied (fig. 6B).

Connection of the pipes: the appliance is fitted with an entrance and an outlet to connect

the pipes. Before connecting the exhaust pipes, check the direction of the air shown on the

external label (fig. 7). Connect the pipes and fix them with appropriate metal clamps (exhaust

pipes and metal clamps have to be supplied by the installer). The pipe (fig. 7A) must be con-

nected with the cookerhood placed in the kitchen, and the pipe (fig. 7B) must be directed

outside the building.

Electrical connection of the hood: the appliance is equipped with a 7m electrical cable with a

six- pin connection at one end. Insert it into the hood’s connection (External Motor version) or

into the SCET-1 central unit (see fig. 8 for the end result).

5