WORKING
6 - channel radio control for cooker hood re-
mote (fig. 10).
Technical data:
Alkaline battery powered: 12v mod. 23A
Operating frequency: 433.92 Mhz
Combinations: 4096
Max. consumption: 25mA
Operating temperature: -20° : +55°C
- To light the cooker hood on or to
light it off press the button:
- To increase the speed up to the
fourth one press the button:
- To reduce the speed up to the
second one press the button:
- To go from a high speed back to
the first one press twice the button:
- To give power to the lights or to
shut them down press the button:
The “light” switch can turn the lights on and
off. after the first touch of the light switch the
lamps turn on at the maximum power. Kee-
ping the switch pressed the intensity of the
light decreases and then increases continuo-
usly. Leaving the switch the brightness re-
mains set up. Touching again the light switch
it is possible to turn the lamps off.
- To set the timer up press the
button:
The LED on the right side will start to flash
(every 5 seconds), the hood will work for 10
minutes at the selected speed and then it li-
ghts automatically off. If the client increases
or reduces the speed while the timer is on,
this is automatically stopped.
Make the electrical connections and connect
the air outlet pipe; place the ceiling-mounted
hood into the niche, by inserting the threaded
bars into the holes (Fig.6); the outer edge of
the hood needs to be perfectly flush with the
false ceiling. Insert the plates and nuts pro-
vided into the threaded bars, making sure to
tighten them securely (Fig. 7); refit the grease
filters and filter cover panels.