Bluelab Dosetronic Solenoid Kit User Manual
Page 38
34
Version S1.3 : 260511
Bluelab Dosetr
onic Solenoid Kit
Bluelab Corporation Limited
8. Check that the piston and cylinder are clean and that the
piston slides in and out of the cylinder with minimal friction. If the
piston or cylinder are not clean, wash and dry both parts thoroughly.
If the piston and cylinder are not thoroughly dry before reassembly,
corrosion will occur and the solenoid valve will stop working.
9. Check the plastic body and flow restrictor for blockages and
clean thoroughly. To check the flow restrictor for blockages: cover the
side hole on the body (the part which has the grommet on it normally)
and run water through from the top of the body. Water should flow out
the bottom of the flow restrictor. If water does not flow through the flow
restrictor it should be cleaned carefully or replaced with a new Bluelab
flow restrictor.
10. Once all parts are dry, reassemble them in the order that you
disassembled them.
11. Filter the solution from the tank and clean the tank thoroughly then put
the solenoid valve back into the grommet on the tank. Make sure the
breather tube is taped up so that it is above the liquid level in the tank
when full.
12. Turn power to the Dosetronic and solenoids back on.
5