beautypg.com

Blu Bathworks TSU131 User Manual

Page 7

background image

2013-07

1 866 907 0122 blubathworks.com

®

6

CARTRIDGE CHANGE
To replace it follow the instruction hereunder.

Shut off water supply to both inlets

Remove the cap (1), remove the grub screw (2), take off the control handle (3) and remove
the screw (4).

Remove the centering insert (5) and unscrew the cap (6).

Pay attention not to lose the O-ring (7) and pull out the plate (8).

Unscrew the flange (9) using 28mm/1

1

/

9

' spanner. Remove the cartridge (10).

Before re-assembling cartridge (10) clean its housing with wet cloth.

Re-assembling the flange (9) and the plate (8), place the O-ring (7) and screw the cap (6).

Re-fit the centering insert (5) and fix it with the screw (4).

Place the control knob (3) and fix it with the grub screw (2)

Re-fit the small cap (1).

IMPORTANT
In case of reduction of flow rate, dismantle the aerator and clean the filter inside or change it.