beautypg.com

Pellet stove adjustments, Fine tuning your stove, Fuel rates – Dansons Group CAN/CSA B365 User Manual

Page 5

background image

3

A

B

FINE TUNING YOUR STOVE

FUEL

FEED RATE

SETTING #1

(LOW)

FUEL

FEED RATE

SETTING #4

(HIGH)

INCREASES

feed rate

DECREASES

feed rate

Do NOT use a metal object to adjust your trim

pods. Try using a plastic non-metallc object

(eg. insulated shaft screwdriver, pen cap, etc.)

Fuel feed rate at the lowest (#1) and highest (#4) settings can be changed by adjusting
the #1 or #4 trim pods located on the control panel.
To INCREASE fuel feed rate, turn the trimmer COUNTER CLOCKWISE.
To DECREASE fuel feed rate, turn the trimmer CLOCKWISE.

WARNING: Adjusting FEED RATE #1 too low (clockwise) may cause your stove to shut down.

PELLET STOVE

ADJUSTMENTS

Once the damper rod is set and your pellets are burning steadily (ie. no
popcorning), you are ready to fine tune your stove. Fine tuning is required
due to the differences in installation configuration, geography, insulation
of the home, and quality of pellets.

First, switch to feed rate #1 by pressing the START /
FEED RATE button until the #1 LED lights up.

Turn the #1 trim pod COUNTER CLOCKWISE until
the dial stops, then turn back to 9-3 o’clock
position as illustrated.

By adjusting these trim pods as described above,
you are ensuring that your stove is now at its
optimal settings. You may need to adjust the
feed rates after a few days of burning.

Turn the #4 trim pod CLOCKWISE until the dial
stops, then turn back to 9-3 o’clock position as
illustrated.

TRIM PODS

WITH FACTORY

DEFAULT SETTINGS

COUNTER-

CLOCKWISE

CLOCKWISE

FUEL RATES

At this point, your stove should still be running on
the #1 setting (low). Let this burn for approximately
10 minutes before making any further adjustments.

IMPORTANT: The #1 and #4 trim pod dials ONLY adjust fuel feed rates 1 and 4.

5